Step 3 - Ground the Generator

Failure to properly ground this generator can result in electrocution.

Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3. A No. 12 AWG (American Wire Gauge) stranded copper wire is generally an acceptable grounding wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth.

Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area.

Figure 3 - Attaching the Grounding Wire to this Generator

Subsequent Use of this Generator

For subsequent uses of this generator after the first use, certain steps still must be completed to prepare it for operation.

IMPORTANT: Be familiar with the procedures described in the previous section titled “Using the Generator for the First Time” of this manual. If not, review this section now.

Step 1 - Verify Oil Level

Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil, it is important to check the oil level in the engine crankcase before each use to ensure that there is sufficient quantity.

1.Verify that this generator is on a level surface.

2.Unscrew the oil filler/dipstick cap from the engine.

3.With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap.

4.Fully insert the dipstick without screwing the filler/dipstick cap and then remove again. There should be oil on the dipstick. If there is no oil on the dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled. (See “Changing/Adding Oil” in the “Maintenance/Care” section of this manual).

5.Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level.

NOTE: The oil capacity for this ACDelco Model AC-G0004 5500 Surge Watts / 5000 Running Watts Electric Start Portable Generator is 1.2 Qt (US).

Model AC-G0004 Oil Capacity (Qt/ fluid oz. /L)

1.2 / 38 / 1.13

Model AC-G0004 Oil Type Recommended

High Detergent Motor Oil, SAE10W-30

Model AC-G0004 5500 Surge Watts / 5000 Running Watts Electric Start Portable Generator

13

Page 13
Image 13
ACDelco AC-G0004 instruction manual Subsequent Use of this Generator, Attaching the Grounding Wire to this Generator