LCD 14.1” inch

Item

 

 

Specification

 

 

 

 

 

 

 

 

Response Time (Optical Rise Time/Fall

25 (rising+falling)

5/11

16

 

Time)msec

 

 

 

 

 

 

 

 

 

 

 

Nominal Input Voltage VDD

+3.3V Typ.

+3.3V

3.3V

 

 

 

 

 

 

 

Typical Power Consumption (watt)

N/A

4.02 (for backlight unit

Total 5.38 Watt (Typ.)

 

 

 

 

only)

@ LCM circuit

 

 

 

 

 

1.28Watt (Typ.),

 

 

 

 

 

Backlight 4.1 Watt

 

 

 

 

 

(Typ.)

 

 

 

 

 

 

 

Weight

420 (440max)

425

390(Typ.) 400(Max)

 

 

 

 

 

 

 

Physical Size(mm)

317.3x242.0x6.0

317.3x242.0x5.9

317.3x242.0x6.5

 

 

 

 

 

 

 

Electrical Interface

1 channel LVDS

1 channel LVDS

1 channel LVDS

 

 

 

 

 

 

 

Support Color

262,144

262,144

262,144

 

 

 

 

 

 

 

Viewing Angle (degree)

 

 

 

 

 

Horizontal: Right/Left

40/40

 

45/45

40/45

 

Vertial: Upper/Lower

10/30

 

20/45

25/30

 

 

 

 

 

 

 

Temperature Range( ° C)

0 to +50

0 to +50

0 to +50

 

Operating

 

-20 to +60

-25 to +60

-20 to +60

 

Storage (shipping)

 

 

 

 

 

 

 

 

 

 

 

 

LCD Inverter

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

Specification

 

 

 

 

 

 

 

Vendor & model name

 

Darfon/V189-301GP

 

 

 

 

 

 

 

 

Brightness conditions

 

N/A

 

 

 

 

 

 

 

 

 

Input voltage (V)

 

9~21

 

 

 

 

 

 

 

 

 

Input current (mA)

 

2.56 (max)

 

 

 

 

 

 

 

 

Output voltage (V, rms)

 

780V (2000V for kick off)

 

 

 

 

 

 

 

 

Output current (mA, rms)

 

6.5 (max)

 

 

 

 

 

 

 

 

 

Output voltage frequency (k Hz)

 

65K Hz (max)

 

 

 

 

 

 

 

 

 

AC Adaptor

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

Specification

 

 

 

 

 

 

 

Input rating

 

90V AC to 264V AC, 47Hz to 63Hz

 

 

 

 

 

 

 

 

Maximum input AC current

 

1.7A

 

 

 

 

 

 

 

 

 

Inrush current

 

220A@115VAC

 

 

 

 

 

220A@230VAC

 

 

 

 

 

 

 

 

Efficiency

 

82% min. @115VAC input full load

 

 

 

 

 

 

 

 

System Power Management

 

 

 

 

 

 

 

 

 

 

 

ACPI mode

 

 

Power Management

 

 

 

 

 

 

Mech. Off (G3)

 

All devices in the system are turned off completely.

 

 

 

 

 

Soft Off (G2/S5)

 

OS initiated shutdown. All devices in the system are turned off

 

 

 

completely.

 

 

 

 

 

 

 

Working (G0/S0)

 

Individual devices such as the CPU and hard disc may be power

 

 

 

managed in this state.

 

 

 

 

 

 

 

 

44