AC Adapter
Item |
| Specification |
|
| |
Vendor & model name | Delta | |
| Hipro | |
| ||
|
| |
Details | 65W | |
| 42W | |
|
| |
|
| |
|
| |
|
|
|
Input Requirements |
|
|
|
| |
Maximum input current (A, | 1.8A max@3.5A/100Vac and 240 Vac | |
@100Vac, full load) |
|
|
|
|
|
Nominal frequency (Hz) | 47 - 63 |
|
|
|
|
Frequency variation range | 47 - 63 |
|
(Hz) |
|
|
|
|
|
Nominal voltages (Vrms) | 90 - 264 |
|
|
| |
Inrush current | The maximum inrush current will be less than 50A and 100A when | |
| the adapter is connected to 100Vac(60Hz) and 240Vac(50Hz) | |
| respectively. |
|
|
| |
Efficiency | High efficiency 85% minimum, at 100~240Vac AC input, full load, | |
| ||
|
|
|
Output Ratings (CV mode) |
|
|
|
| |
DC output voltage | Offers constant voltage 19.0V output source with 150W max output | |
| power capacity. | |
Noise + Ripple | ||
|
|
|
Output current | 0 A (min.) | 3.5A (max.) |
|
|
|
Output Ratings (CC mode) |
|
|
DC output voltage | 18.0 ~ 20.0 |
|
|
|
|
Constant output | 7.9A |
|
|
|
|
Dynamic Output Characteristics |
| |
3 sec. (@115 Vac and 230Vac full load) | ||
|
| |
Hold up time | 5ms min. (@115 Vac input, full load) | |
|
|
|
Over Voltage Protection | 25V |
|
(OVP) |
|
|
|
| |
Short circuit protection | Output can be shorted without damage, and auto recovery | |
|
| |
Electrostatic discharge | 15kV (at air discharge) | |
(ESD) | 8kV (at contact discharge) | |
|
|
|
Dielectric Withstand Voltage |
|
|
|
| |
Primary to secondary | 4242 Vdc for 1 second- | |
|
| |
Leakage current | 60uA at 240Vac/60Hz | |
|
| |
Regulatory Requirements | 1. FCC class B requirements (USA) | |
| 2. VDE class B requirements (German) | |
| 3. VCCI classII requirements (Japan) | |
|
|
|
Chapter 1 | 37 |