Chapter 4 83
Undetermined Problems
The diagnostic problems does not identify which devices fail, which devices are incorrectly installed, whether a
short circuit happens, or whether the system is inoperative.
Note: Verify if all devices attached are supported by the computer.
Note: Verify if the power supply used at the time of failure is operating correctly. You can refer to “Power
System Check”.
Follow the procedures below to isolate the failing FRU. Do not isolate non-defective FRU.
1. Power off the computer.
2. Visually check the devices. If any problems are found, replace the FRU.
3. Remove or disconnect all of the following devices:
Non-Acer devices
Printer, mouse, and other external devices
Battery Pack
Hard disk drive
DIMM
CD-ROM / Diskette drive module
PC cards
4. Power on the computer.
5. Determine if the problem has been resolved.
6. If the problem does not recur, reconnect the removed devices one at a time until you find the failed FRU.
7. If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU.
System board
LCD assembly