Acer AL1951 Screen image is not centered or sized, Adjust pixel frequency CLOCK and, properly

Models: AL1951

1 20
Download 20 pages 28.03 Kb
Page 15
Image 15
Screen image is not centered or sized

Screen image is not centered or sized

*Adjust pixel frequency (CLOCK) and

properly.

FOCUS or press hot-key (AUTO)

Picture has color defects

*Adjust RGB color or select color

(white does not look white)

temperature

Horizontal or vertical disturbances on

*Use win 95/98 shut-down mode

the screen

Adjust CLOCK and FOCUS or

 

perform hot- key (AUTO-key).

CLOCK (pixel frequency) controls the number of pixels scanned by one horizontal sweep. If the frequency is not correct, the screen shows vertical stripes and the picture has not correct width.

FOCUS adjusts the phase of the pixel clock signal. With a wrong phase adjustment the picture has horizontal disturbances in light picture.

For FOCUS and CLOCK adjustment use “dot-pattern” or win 95/98 shut-down mode pattern.