Acer

Acer –LCD-H243H

Temperature range

: -20°C to 60°C

Humidity range

: 5% to 90%

2.1.3Altitude note 2

Operating

10000 ft (Ta=50, t=24h)

Storage

30000 ft (Ta=30, t=24h )

Note 1: Temperature and relative humidity range must be in the area shown as the following figure due to panel limited

Note 2: Altitude spec must not over panel spec.

2.2 Safety, EMC, Ergonomics and Compatibility Requirements

Safety & EMC

MET, CB, Bauart, CCC, FCC, CE, VCCI-B

 

 

Ergonomics

MPRII ISO13406-2

 

 

Compatibility

Windows 95/98/Me/2000, Windows XP, Window Vista

 

 

Power Management

Energy Star

 

 

2.3 Electrostatic Discharge Requirements

The subject unit must withstand ±8KV for contact discharge and ±15KV for air discharge of Electrostatic Discharge and meet the standard of IEC61000-4-2(EN55024). (without discharge on VGA/DVI pin)

2.4 Reliability

The MTBF of this product shall be greater than 25,000 hours excluding the LCD panel. The LCD panel life which is defined as the time period for the maximum luminance to reduce to 50% of the initial value is 40,000 hours minimum at the condition of displaying an all WHITE field at mid Brightness and Contrast settings.

3. Electrical and Optical Characteristics and Performance

3.1 Main Power Supply

3.1.1AC Input Voltage Range

It is a universal type and the input voltage range is from 100 ~ 240Vrms

3.1.2 AC Input Current

1.5A (max) at 100VAC input

0.8A (max) at 240VAC input

AC Frequency Range

The frequency range is from 50Hz to 60Hz

Inrush Current

a. 40A max at cold-start, 25°C, DC output full-loading and 100Vac input b. 60A max at cold-start, 25°C, DC output full-loading and 240Vac input

Regulator Efficiency

4

Page 5
Image 5
Acer H243H Electrical and Optical Characteristics and Performance, Safety, EMC, Ergonomics and Compatibility Requirements