Acer M5811 manual USB eModule Error Messages, Message Displayed Description

Models: M5811

1 101
Download 101 pages 51.42 Kb
Page 61
Image 61

USB eModule Error Messages

 

Message

Description

 

Displayed

 

 

 

 

 

 

Warning!

This message is displayed when a non-bootable USB device is enumerated and disabled

 

Unsupported

by the BIOS.

 

USB device

 

 

found and

 

 

disabled!

 

 

 

 

 

Warning! Port

This message is displayed to indicate that port 60h/64h emulation mode cannot be enabled

 

60h/64h

for this USB host controller. This condition occurs if USB KBC emulation option is set for

 

emulation is

non-SMI mode.

 

not supported

 

 

by this USB

 

 

Host

 

 

Controller!

 

 

 

 

 

Warning! EHCI

This message is displayed to indicate that EHCI controller is disabled because of incorrect

 

controller

data structure. This condition occur if the USB host controller needs 64-bit data structure

 

disabled. It

while the USB is ported with 32-bit data structure.

 

requires 64bit

 

 

data support in

 

 

the BIOS.

 

 

 

 

SMBIOS eModule Error Messages

 

Message Displayed

Description

 

 

 

 

Not enough space in Runtime area!!. SMBIOS data

This message is displayed when the size of the

 

will not be available.

SMBIOS data exceeds the available SMBIOS

 

 

runtime storage size

 

 

 

CPU eModule Error Messages

 

 

Message Displayed

Description

 

 

 

 

Warning! This system board does not support the

This message is displayed when the power

 

power requirements of the installed processor. The

requirements of the board do not match the power

 

processor will be run at a reduced frequency, which

requirement of the CPU.

 

will impact system performance. area!!. SMBIOS

 

 

data will not be available.

 

 

 

 

MPS Table (Multi-processor) eModule Error Messages

Message Displayed

Description

 

 

Insufficient Runtime space for MPS data! System

This message is displayed when there is not enough

may operate in PIC or Non-MPS mode.

space in the 0F000h runtime area for creating MPS

 

table.

 

 

Chapter 4

54

Page 61
Image 61
Acer M5811 manual USB eModule Error Messages, Message Displayed Description