- 11 -
Brightness At R/G/B saturated
condition 250 cd/m
2
(typ.),200
cd/m
2
(min) √
Test Condition:
Set Contrast at
50, Brightness
at 100, Color at
User preset.
Response time Rising + Falling time On/off:5 ms
(typ.),10ms(max) √
Test
Equipment:
Westar TRD
100 or equal
level
equipment ;
At Contrast ratio = 10 R/L: 85/85 degrees (typ.)
70/70 degrees (min) √
Viewing angle At Contrast ratio = 10 U/D: 75/85 degrees (typ.)
60/70 degrees(min) √
CIE coordinate of White (0.31, 0.33) +/- (0.03,
0.03) √
Display colors 16.7 Millions colors √ 6 bit+Hi-FRC
3.3.2 Brightness Adjustable Range
Item Condition Spec OK
N.A
Remark
Brightness adjustable
range
At default contrast level
(saturate point) & Full-
white color pattern
(Max. brightness value –
Min.
brightness
value)
100 cd/
√
3.3.3 Acoustical Noise
Item Condition Spec OK
N.A
Remark
Acoustical Noise At 30 cm distance 22 dB/A √ Refer to C326
3.3.4 Environment
Item Condition Spec OK
N.A
Remark
Operating 0 ~ +40 √
Temperature Non-operating -20 ~ +65 √
Operating 20 ~ 80% √ Non-
condensing
Humidity Non-operating 20 ~ 80% √ Non-
condensing
Operating 12,000 feet at 25°C √ W ithout
packing
Altitude Non-operating 40,000 feet at -30 °C √ With packing