Installation of CAN

Adapter Board

 

READ AND UNDERSTAND BEFORE

IMPORTANT

INSTALLING. IF THERE ARE ANY

 

9640UB UPGRADE

 

Small needle nose pliers (not included)

IMPORTANT

 

may be helpful to remove jumpers.

 

 

When removing jumpers metal

 

contacts could fall out causing a

 

short.

! CAUTION

Make sure not to bend pins.

 

Make sure no jumpers or components on circuit board are touching adapter board or are loose that could cause a short.

QUESTIONS CALL 1-800-228-7667

STEP 1

Disconnect Scan Tool and cables from vehicle.

!When working with circuit boards CAUTION make sure to avoid touching internal

components.

STEP 4

Remove jumpers from circuit board inside Scan Tool.

IMPORTANT

If required bendtest point and transistor so that they do not touch adapter board due to the chances of a short. Make sure not to break leads on components.

STEP 2

Remove 1 phillips screw and 6 AAA batteries.

STEP 3

Remove 6 phillips screws from back cover using a #1 screwdriver.

Remove 14 Jumpers

Remove 1 Jumper

Remove 1 Jumper

DO NOT Remove Jumpers

STEP 5

Inspect connector pins on circuit board making sure pins are straight and not bent.

Bent Pins

! CAUTION

Before installing CAN adapter board

straighten any bent connector pins.

 

STEP 6

Remove CAN adapter board from anti-static bag making sure to handle adapter board by the edges.

STEP 7

Place CAN adapter board on Scan Tool circuit board pins. DO NOT push adapter board down. Check that all pins are aligned with connectors on adapter board. Then gently and evenly push CAN adapter board at the pressure points indicated onto Scan Tool circuit board until completely down.

Pressure Points

Test Point

Transistor

STEP 8

Replace back cover, batteries and battery cover in reverse order they were removed. Install software as shown on other side of page.

! CAUTION Do not overtighten phillips screws.

Page 1
Image 1
Actron 9640UB Upgrade manual Installation of can Adapter Board, Step