19

If your AcuRite product does not operate properly after trying

the troubleshooting steps, visit www.AcuRite.com or call

(877) 221-1252 for assistance.

Problem Possible Solution
Inaccurate
temperature or
humidity
Make sure both the display unit and 5-in-1 sensor
are placed away from any heat sources or vents (see
page 11).
Make sure both units are positioned away from
moisture sources (see page 11).
Make sure 5-in-1 sensor is mounted at least 5 ft off of
the ground.
• Calibrate indoor and outdoor temperature and
humidity (see page 20).
No rainfall
• Check to ensure the rain gauge stabilizer (plastic tab)
has been removed from the bottom of the sensor (see
page 7).
• Clear debris, such as leaves, out of the rain collector
funnel and debris screen.
• Calibrate the Rain Gauge (see page 21).
Inaccurate wind
readings
What is wind reading being compared to? Pro
weather stations are typically mounted at 30 ft high
or more. Make sure to compare data using a sensor
positioned at the same mounting height.
Check location of the sensor. Ensure it’s mounted a
minimum of 5 ft in the air with no obstructions around
it (within several feet).
Ensure wind cups are spinning freely. If they hesitate
or stop try lubricating with graphite powder or spray
lubricant.
Display screen
not working
Check that the batter ies are installed correctly.
Batteries may need to be replaced.
Reset the display by pressing the reset button, located
on the back of the display unit. Date and time will
need to be entered after a reset.
Troubleshooting