4 SPECIFICATIONS
Table 6 and Table 7 lists the specifications for the module.
Table 6. Electrical and Mechanical Specifications
PARAMETER | SPECIFICATION | REMARKS |
Electrical |
|
|
|
|
|
Input Voltage | +5 VDC | Backplane connector |
|
|
|
Input power (10/100 Mb/s) | 1.75 W max. | Normal operation |
|
|
|
Input power (1000 Mb/s) | 2.2 W max. | Normal operation |
|
|
|
Mechanical |
|
|
|
|
|
Chassis Compatibility | OptEnet Media Converter | All modular systems |
|
|
|
Module Retention | Captive thumbscrews |
|
|
|
|
Dimensions (H⋅W⋅D) | 1.14 in.⋅ 8.07 in.⋅ 7.4 in. |
|
| (2.89 cm ⋅ 20.5 cm ⋅ 18.8 cm) |
|
|
|
|
Weight | 0.27 lb. (122 g.) |
|
|
|
|
Electrical Signal Interface |
|
|
|
|
|
RJ45 | Two twisted pair | 10/100 Mb/s |
|
|
|
RJ45 | Four twisted pair | 1000 Mb/s |
|
|
|
Optical Signal Interface |
|
|
|
|
|
LC | Singlemode 1410 – 1610 nm * |
|
|
|
|
* - Refer to the OptEnet SFP Transceiver Specifications listed in Related Publications, for optical specifications.
Table 7. Module Environmental Specifications
PARAMETER | SPECIFICATION | REMARKS |
Operating Conditions | 41°F to +104°F (5°C to +40°C) | Per Telcordia |
|
|
|
Short Term Conditions | +23°F to +122°F (−5°C to +50°C) | Per Telcordia |
|
|
|
Storage Conditions | −40°F to +185°F (−40°C to +85°C) at 5% to 95% RH | |
|
|
|
5 POWER-UP/CHECK OUT PROCEDURE
Media Converter Modules are powered up as soon as power is applied to the chassis. The POWER indicator (GREEN LED) on the converter module should light to indicate that VDC power is applied to the media converter. If POWER indicator does not come on, verify that power connections between the Media Converter Module and the power supply are secure. Verify that there is power present at the source. If this procedure does not resolve the problem, replace the cable or power supply.
Page 10