ADC ADX200, ADX201 manual Specifications, Spec Sheet, O r d e r i n g I n f o r m a t i o n

Models: ADX201 ADX200

1 2
Download 2 pages 27.71 Kb
Page 2
Image 2
Spec Sheet

Spec Sheet

O r d e r i n g I n f o r m a t i o n

Description

Catalogue Number

ADX200

 

1 rack (height) unit, for mounting in ETSI/19” rack

 

Without interface cards

ADX-7077 2 018-00

With 4 interface cards

ADX-7077 2 017-00

ADX201

 

2 rack (height) units, for mounting in ETSI/19” rack

 

Without interface cards

ADX-7077 2 020-00

With 8 interface cards

ADX-7077 2 019-00

Accessories

 

Blank faceplate

ADX-7077 2 010-01

Interface card with LSA-PLUS®connector

ADX-7077 2 016-00

Horizontal cable management tray

6527 1 006-01

Specifications

Physical Design

Modular design includes:

STM-1 module

ADX200 19" version 1 RU (HE) for four interface cards, 32 E1s

ADX201 19" version 2 RU (HE) for eight interface cards, 64 E1s

Hot pluggable interface cards, with eight E1 interfaces each. Interface card for unshielded twisted pair, using LSA-PLUS®connection technology

Up to two STM-1 interface (optical or electrical) using small-form-factor pluggable (SFP)

Size:

19" 1RU (HE) and 2RU (HE)

Weight:

2 kg

Power:

Power-over-Ethernet (PoE), 802.3af, < 14 Watt, DC 48V and redundant

 

power supply via external converter

Slots:

Two SFPs, eight interface cards (2RU) and four interface cards (1RU)

Environmental

 

Operations:

ETS300-019-2-3 class 3.1

Storage:

ETS300-019-2-1 class 1.2

Transport:

ETS300-019-2-2 class 2.3

Interfaces:

64x E1, multiple mapping schemes are supported including 2Mbps framed,

 

2Mbps unframed, (2) STM-1, optical (IR/SR/LR) and electrical via SFP modules

Protection:

1+1 MSP

Reliability:

MTBF > 30 years.

Management:

Web-based integrated craft interface (ICI) including the support of smart default settings

 

IP based management

 

Local management access via 10/100BaseT interface

 

SNMP with trap messages supported

 

Non-volatile software and database stores including back-up and restore

Timing:

E1 and line timing (Timing Marker) support

 

Integrated SDH equipment slave clock (SEC) according to ITU G.813

 

Re-timing option on the E1 interfaces

Standards:

In compliance with the ITU, ETSI, IEC, IEEE, IETF standards for E1 and SDH equipment

Web Site: www.adc.com

From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080

Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our Web site.

ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101

Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer

102189AE 7/06 Original © 2006 ADC Telecommunications, Inc. All Rights Reserved