Page 4 of 4
Table 
| FIELD | TYPE | OPTIONS | DESCRIPTION | DEFAULT | 
| Unit Equipment | Toggle | Equipped | Sets all other fields to default values, | UNEQUIPPED | 
| State | 
 | 
 | establishes communication with the MPU, | 
 | 
| 
 | 
 | 
 | and allows the MPU to process equipment | 
 | 
| 
 | 
 | 
 | alarms. Module must be set to EQUIPPED | 
 | 
| 
 | 
 | 
 | before remaining selections are allowed. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | UNEQUIPPED | No communication with the MPU. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| Unit Service | Toggle | IN SERVICE | Places the unit in service and allows | OUT OF SERVICE | 
| State | 
 | 
 | equipment alarm reporting by the MPU. | 
 | 
| 
 | 
 | 
 | Must be set to IS for reporting of equipment | 
 | 
| 
 | 
 | 
 | alarms. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | OUT OF | Removes the unit from service and stops | 
 | 
| 
 | 
 | SERVICE | equipment alarm reporting by the MPU. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| MUX Protect | Toggle | Protected | Designates that equipment APS is available. | UNPROTECTED | 
| Status | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | UNPROTECTED | Designates that equipment APS is not | 
 | 
| 
 | 
 | 
 | available. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| Facility Service | Toggle | IN SERVICE | Allows facility alarm reporting by the MPU. | OUT OF SERVICE | 
| State | 
 | 
 | Must be set to IS for reporting of facility | 
 | 
| 
 | 
 | 
 | alarms. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | OUT OF | Stops facility alarm reporting by the MPU. | 
 | 
| 
 | 
 | SERVICE | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| Transmit LBO | Toggle | IN | Inserts a Line Build Out (LBO) equivalent to | IN | 
| Setting | 
 | 
 | 0 to 224 feet. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | OUT | Inserts a 225 to 450 ft. LBO in the DS3 | 
 | 
| 
 | 
 | 
 | circuit. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| DS1 Loopback | Toggle | A type of stuff indicator bit based on TR- | ||
| Mode* | 
 | 
 | 
 | |
| 
 | 
 | 
 | loopback signal. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | A type of stuff indicator bit invented by | 
 | |
| 
 | 
 | 
 | NEC. An  | 
 | 
| 
 | 
 | 
 | signal. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | FEAC | FEAC (Far End Alarm and Control) is a 16- | 
 | 
| 
 | 
 | 
 | bit code based on  | 
 | 
| 
 | 
 | 
 | send alarm or status information. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| DS3 Framing | Display | M13 or  | This field displays what DS3 path framing | None | 
| Format Status | only | 
 | format has been detected. Paths with the | 
 | 
| 
 | 
 | 
 | M13 format have their performance | 
 | 
| 
 | 
 | 
 | monitored for  | 
 | 
| 
 | 
 | 
 | with  | 
 | 
| 
 | 
 | 
 | performance monitored for both near- and | 
 | 
| 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
* Note: The loopback type configured in this field involves the DS3 MUX only.