FIELD | TYPE | OPTIONS | DESCRIPTION | DEFAULT |
Unit Equipment | Toggle | Equipped | Sets all other fields to default values, | UNEQUIPPED |
State |
|
| establishes communication with the MPU, |
|
|
|
| and allows the MPU to process equipment |
|
|
|
| alarms. Module must be set to EQUIPPED |
|
|
|
| before remaining selections are allowed. |
|
|
|
|
|
|
|
| UNEQUIPPED | No communication with the MPU. |
|
|
|
|
|
|
Unit Service | Toggle | IN SERVICE | Places the unit in service and allows | OUT OF SERVICE |
State |
|
| equipment alarm reporting by the MPU. |
|
|
|
| Must be set to IS for reporting of equipment |
|
|
|
| alarms. |
|
|
|
|
|
|
|
| OUT OF | Removes the unit from service and stops |
|
|
| SERVICE | equipment alarm reporting by the MPU. |
|
|
|
|
|
|
MUX Protect | Toggle | Protected | Designates that equipment APS is available. | UNPROTECTED |
Status |
|
|
|
|
|
|
|
|
|
|
| UNPROTECTED | Designates that equipment APS is not |
|
|
|
| available. |
|
|
|
|
|
|
Facility Service | Toggle | IN SERVICE | Allows facility alarm reporting by the MPU. | OUT OF SERVICE |
State |
|
| Must be set to IS for reporting of facility |
|
|
|
| alarms. |
|
|
|
|
|
|
|
| OUT OF | Stops facility alarm reporting by the MPU. |
|
|
| SERVICE |
|
|
|
|
|
|
|
Transmit LBO | Toggle | IN | Inserts a Line Build Out (LBO) equivalent to | IN |
Setting |
|
| 0 to 224 feet. |
|
|
|
|
|
|
|
| OUT | Inserts a 225 to 450 ft. LBO in the DS3 |
|
|
|
| circuit. |
|
|
|
|
|
|
DS1 Loopback | Toggle | A type of stuff indicator bit based on TR- | ||
Mode* |
|
|
| |
|
|
| loopback signal. |
|
|
|
|
|
|
|
| A type of stuff indicator bit invented by |
| |
|
|
| NEC. An |
|
|
|
| signal. |
|
|
|
|
|
|
|
| FEAC | FEAC (Far End Alarm and Control) is a 16- |
|
|
|
| bit code based on |
|
|
|
| send alarm or status information. |
|
|
|
|
|
|
DS3 Framing | Display | M13 or | This field displays what DS3 path framing | None |
Format Status | only |
| format has been detected. Paths with the |
|
|
|
| M13 format have their performance |
|
|
|
| monitored for |
|
|
|
| with |
|
|
|
| performance monitored for both near- and |
|
|
|
|
| |
|
|
|
|
|
* Note: The loopback type configured in this field involves the DS3 MUX only.