Page 2 of 3
| ODS2 CONFIGURATION | |
| Group: 3 |
|
Unit Equip State : EQUIPPED | T2 Service State : IS | |
Unit | Service State: IS | BER Alarm Thresh: |
Unit | Protect State: UNPROTECTED | BER Switch Thresh: |
T1 |
|
| Service | Line |
PARAMETERS | Provision State | Code Circuit ID | ||
|
| ========= ======= | ==== ==================== | |
T1 | #1: | YES | OOS | AMI |
T1 | #2: | YES | OOS | AMI |
T1 | #3: | YES | OOS | AMI |
T1 | #4: | YES | OOS | AMI |
T1 |
| Remote Pulse | Remote | Remote PPS |
PARAMETERS | Equalization | Frame Format | Threshold | |
|
| =========== | ============ | ============= |
T1 | #1: | N/A | N/A | N/A |
T1 | #2: | N/A | N/A | N/A |
T1 | #3: | N/A | N/A | N/A |
T1 | #4: | N/A | N/A | N/A |
Remote Housekeeping Labels: |
|
| ||
Working Card | HSKP1: | HSKP2: | ||
Protect Card | HSKP1: N/A |
| HSKP2: N/A | |
|
| Press |
Figure
Table
FIELD | TYPE | OPTIONS | DESCRIPTION | DEFAULT |
Group | Toggle | 1, 2, 3, 4, 5, 6, or 7 | Specifies the module’s group number | 1 |
|
|
| designated on the chassis. |
|
|
|
|
|
|
Unit Equipment | Toggle | Equipped | Establishes communication with MPU. Module | UNEQUIPPED |
State |
|
| must be set to EQUIPPED before remaining |
|
|
|
| selections are allowed. Sets all other fields to |
|
|
|
| default values and allows MPU to process |
|
|
|
| equipment alarms. |
|
|
|
|
|
|
|
| UNEQUIPPED | No communication with MPU. |
|
|
|
|
|
|
Unit Service State | Toggle | IS | Places the unit in service and allows equipment | OOS |
|
|
| alarm reporting by the MPU. Must be set to IS |
|
|
|
| for reporting of equipment alarms. |
|
|
|
|
|
|
|
| OOS | Removes unit from service and stops equipment |
|
|
|
| alarm reporting by the MPU. |
|
|
|
|
|
|
Unit Protect State | Toggle | PROTECTED | Designates that equipment APS is available. | UNPROTECTED |
|
|
|
|
|
|
| UNPROTECTED | Designates that equipment APS is not available. |
|
|
|
|
|
|
|
|
|
| (continued) |