Page 3 of 3
Table
FIELD | TYPE | OPTIONS | DESCRIPTION | DEFAULT |
T2 Service State | Toggle | Leave this field at OOS at this time to avoid undesirable reporting of alarms. | OOS | |
|
| Select IS after completing the remaining configurations. |
| |
|
|
|
|
|
BER Alarm | Toggle | Set to OFF or set between | The average Bit Error Ratios of both the | |
Threshold |
| incoming optical signals are monitored by the |
| |
|
|
| ODS2. By monitoring BERs, the ODS2 is |
|
|
|
| capable of triggering a minor alarm when any of |
|
|
|
| the monitored signals degrades below the BER |
|
|
|
| threshold level. |
|
|
|
|
|
|
BER Switch | Toggle | Set between | This sets the threshold at which the APS will be | |
Threshold |
| 10 | executed. |
|
|
|
| ||
|
|
|
|
|
Provision | Toggle | YES | Brings up T1 default settings and allows | NO |
|
|
| configuration changes. |
|
|
|
|
|
|
(set for each T1) |
| NO | Facility not provisioned. |
|
|
|
|
|
|
T1 Service State | Toggle | Leave this field at OOS at this time to avoid undesirable reporting of alarms. | OOS | |
|
| Select IS after completing the remaining configurations. |
| |
|
|
|
|
|
Line Code | Toggle | AMI | Alternate Mark Inversion | AMI |
|
|
|
|
|
(set for each T1) |
| B8ZS | Bipolar |
|
|
|
|
|
|
Circuit Identifier | Input | Enter up to 20 characters | Use alphanumeric characters; embedded | None |
|
| or leave blank. | hyphens are allowed. |
|
(set for each T1) |
|
|
|
|
|
|
|
|
|
Remote Pulse | Toggle | The DS1 signal output provides standard DSX | ||
Equalization |
| signal levels which can be compensated for at |
| |
|
| various distances (i.e., cable length). |
| |
|
| APPL. |
|
|
|
|
|
|
|
Remote Frame | Fixed | Locked at NOT APPL. |
| NOT APPL |
Format |
|
|
|
|
|
|
|
|
|
Remote PPS (Path | Fixed | Locked at NOT APPL. |
| NOT APPL |
Protection Switch) |
|
|
|
|
Threshold |
|
|
|
|
|
|
|
|
|
T2 Service State | Toggle | IS | Places facility in service and allows T2 alarm | OOS |
|
|
| reporting by the MPU. |
|
|
|
|
|
|
|
| OOS | Removes facility from service and stops T2 |
|
|
|
| alarm reporting by the MPU. |
|
|
|
|
|
|
T1 Service State (set | Toggle | IS | Places facility in service and allows T1 alarm | OOS |
for each T1) |
|
| reporting by the MPU. |
|
|
|
|
|
|
|
| OOS | Removes facility from service and stops T1 |
|
|
|
| alarm reporting by the MPU. |
|
|
|
|
|
|