Page 6 of 7
Table
FIELD | TYPE | OPTIONS | DESCRIPTION | DEFAULT |
Network Keep Alive | Toggle | D2 HLXR only: AIS | If the system detects a LOS (Loss of Signal) from | AIS |
|
|
| the customer, an AIS or customer disconnect |
|
|
|
| indication (DS1 Idle Code) is sent to the network. |
|
|
|
| An AIS is sent if UNFRAMED is selected in the |
|
|
|
| T1 Framing Format field. A DS1 Idle Code is sent |
|
|
|
| if a framed format (Ft, SF or ESF) is selected in |
|
|
|
| the T1 Framing Format field. |
|
|
|
|
|
|
|
| All other HLXRs: | If the system detects a LOS (Loss of Signal) from |
|
|
| AIS | the customer, an AIS is sent to the network. |
|
|
|
|
|
|
|
| LOOPBACK | If the system detects a LOS from the customer, the |
|
|
|
| signal is automatically looped back towards the |
|
|
|
| network. |
|
|
|
|
|
|
|
| DS1 CUTOFF | If the system detects a LOS from the customer, the |
|
|
|
| signal is cut off and no pattern is transmitted to the |
|
|
|
| network. |
|
|
|
|
|
|
HLXR Simplex | Toggle | UNIT SWITCH | Defaults to the simplex power hardware | UNIT SWITCH |
Power* (D1/D2/D2A- |
|
| configuration setting on the HLXR. Refer to the | (NOT APPL for |
SP/D3/ D3A HLXR |
|
| Soneplex Version D and Version E HLXR Remote | D2A, D4, E4, F4, |
only) |
|
| System Operation and Maintenance Manual, listed | or G4 HLXR) |
|
|
| under Related Publications at the beginning of this |
|
|
|
| manual, for more information. |
|
|
|
|
|
|
|
| ENABLED | A 60 mA constant current is applied to the DS1 |
|
|
|
| terminals for powering NIDs or CSUs. Overrides |
|
|
|
| the hardware setting on the HLXR. |
|
|
|
|
|
|
|
| DISABLED | Turns simplex power off. Overrides the hardware |
|
|
|
| setting on the HLXR. |
|
|
|
|
|
|
DS0 Channel | Input | Enter “B” for DS0 | Blocking a channel causes the channel blocking | Blank |
|
| Channel blocking or | pattern to be transmitted in both directions on the |
|
|
| leave blank for | selected channel. |
|
|
| normal operation for |
|
|
|
| each of the 24 DS0 |
|
|
|
| channels. |
|
|
|
|
|
|
|
Versions D, E, and G | Input | Enter an | Enter the pattern you want to use to block the | Blank (Version C |
HLXC: Blocked |
| programmable code | channels you selected in the DS0 Channel field. | HLXC is fixed at |
Channel Pattern |
| consisting of 1s and |
| an all 1s pattern |
|
| 0s. |
| and is not |
|
|
|
| configurable) |
|
|
|
|
|
Remote | Input | Enter up to 8 | These fields can be edited to create customized | Blank |
Housekeeping Labels |
| alphanumeric | labels. When a housekeeping alarm (door ajar, water |
|
|
| characters. | on the floor, fire alarm, etc.) occurs, the name |
|
|
|
| assigned is displayed in the condition column of the |
|
|
|
| Alarm History and Active Alarms screens. |
|
|
|
|
|
|
*Note: HLXC and HLXR Switch Settings (HLXC
(continued)
© 2000, ADC Telecommunications, Inc.