Page 6 of 7
Table 
| FIELD | TYPE | OPTIONS | DESCRIPTION | DEFAULT | 
| Network Keep Alive | Toggle | D2 HLXR only: AIS | If the system detects a LOS (Loss of Signal) from | AIS | 
| 
 | 
 | 
 | the customer, an AIS or customer disconnect | 
 | 
| 
 | 
 | 
 | indication (DS1 Idle Code) is sent to the network. | 
 | 
| 
 | 
 | 
 | An AIS is sent if UNFRAMED is selected in the | 
 | 
| 
 | 
 | 
 | T1 Framing Format field. A DS1 Idle Code is sent | 
 | 
| 
 | 
 | 
 | if a framed format (Ft, SF or ESF) is selected in | 
 | 
| 
 | 
 | 
 | the T1 Framing Format field. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | All other HLXRs: | If the system detects a LOS (Loss of Signal) from | 
 | 
| 
 | 
 | AIS | the customer, an AIS is sent to the network. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | LOOPBACK | If the system detects a LOS from the customer, the | 
 | 
| 
 | 
 | 
 | signal is automatically looped back towards the | 
 | 
| 
 | 
 | 
 | network. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | DS1 CUTOFF | If the system detects a LOS from the customer, the | 
 | 
| 
 | 
 | 
 | signal is cut off and no pattern is transmitted to the | 
 | 
| 
 | 
 | 
 | network. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| HLXR Simplex | Toggle | UNIT SWITCH | Defaults to the simplex power hardware | UNIT SWITCH | 
| Power* (D1/D2/D2A- | 
 | 
 | configuration setting on the HLXR. Refer to the | (NOT APPL for | 
| SP/D3/ D3A HLXR | 
 | 
 | Soneplex Version D and Version E HLXR Remote | D2A, D4, E4, F4, | 
| only) | 
 | 
 | System Operation and Maintenance Manual, listed | or G4 HLXR) | 
| 
 | 
 | 
 | under Related Publications at the beginning of this | 
 | 
| 
 | 
 | 
 | manual, for more information. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | ENABLED | A 60 mA constant current is applied to the DS1 | 
 | 
| 
 | 
 | 
 | terminals for powering NIDs or CSUs. Overrides | 
 | 
| 
 | 
 | 
 | the hardware setting on the HLXR. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | DISABLED | Turns simplex power off. Overrides the hardware | 
 | 
| 
 | 
 | 
 | setting on the HLXR. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| DS0 Channel | Input | Enter “B” for DS0 | Blocking a channel causes the channel blocking | Blank | 
| 
 | 
 | Channel blocking or | pattern to be transmitted in both directions on the | 
 | 
| 
 | 
 | leave blank for | selected channel. | 
 | 
| 
 | 
 | normal operation for | 
 | 
 | 
| 
 | 
 | each of the 24 DS0 | 
 | 
 | 
| 
 | 
 | channels. | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| Versions D, E, and G | Input | Enter an  | Enter the pattern you want to use to block the | Blank (Version C | 
| HLXC: Blocked | 
 | programmable code | channels you selected in the DS0 Channel field. | HLXC is fixed at | 
| Channel Pattern | 
 | consisting of 1s and | 
 | an all 1s pattern | 
| 
 | 
 | 0s. | 
 | and is not | 
| 
 | 
 | 
 | 
 | configurable) | 
| 
 | 
 | 
 | 
 | 
 | 
| Remote | Input | Enter up to 8 | These fields can be edited to create customized | Blank | 
| Housekeeping Labels | 
 | alphanumeric | labels. When a housekeeping alarm (door ajar, water | 
 | 
| 
 | 
 | characters. | on the floor, fire alarm, etc.) occurs, the name | 
 | 
| 
 | 
 | 
 | assigned is displayed in the condition column of the | 
 | 
| 
 | 
 | 
 | Alarm History and Active Alarms screens. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
*Note: HLXC and HLXR Switch Settings (HLXC 
(continued)
© 2000, ADC Telecommunications, Inc.