Page 3 of 3
Table
FIELD | TYPE | OPTIONS | DESCRIPTION | DEFAULT |
T1 Provision | Toggle | YES | Brings up T1 default settings and | NO |
|
|
| allows configuration changes. |
|
|
|
|
|
|
|
| NO | Prevents configuration settings. |
|
|
|
|
|
|
T1 Service State | Toggle | Leave this field at OOS at this time to avoid undesirable reporting of alarms. Place the circuit In- | ||
|
| Service after complete the remaining configurations. |
| |
|
|
|
|
|
T1 Line Code | Toggle | AMI | Alternate Mark Inversion | AMI |
|
|
|
|
|
|
| B8ZS | Bipolar |
|
|
|
|
|
|
Pulse Equalization | Toggle | The DS1 signal output provides | ||
|
| standard DSX signal levels which |
| |
|
| can be compensated for various |
| |
|
|
| distances. |
|
|
|
|
|
|
T1 BER | Toggle | T1 BER Threshold can be set between | When the Bit Error Rate threshold | |
Threshold |
| is exceeded, an alarm is triggered. |
| |
Loopback | Input | Enter a number from 0 to 255. | This field represents the number of | 30 |
Timeout Period |
|
| minutes that the loopback remains |
|
|
|
| in effect before reverting to the |
|
|
|
| normal |
|
|
|
| Setting the loopback |
|
|
|
| period to 0 disables the |
|
|
|
| feature. |
|
|
|
|
|
|
Circuit Identifier | Input | Up to 20 characters. | This represents the customer’s | None |
|
|
| circuit ID. The first and last |
|
|
|
| characters must be alpha or |
|
|
|
| numeric; middle characters can be |
|
|
|
| alpha, numeric or hyphens. |
|
|
|
|
|
|
T1 Service State | Toggle | IS | Allows T1 alarms to be reported to | OOS |
|
|
| the MPU. |
|
|
|
|
|
|
|
| OOS | Prevents T1 alarms from being |
|
|
|
| reported to the MPU. |
|
|
|
|
|
|
© 2000, ADC Telecommunications, Inc.