ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-533

Page 4 of 5

Table 533-1. RLXIOR Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT*

Span Power

Toggle

UNIT SWITCH

Stops span power on the RLXIOR.

ENABLED

Setting**

 

 

 

 

 

 

 

 

 

 

 

ENABLED

Enables span power using the on-board

 

 

 

 

switch settings (–130V or ±130V). The

 

 

 

 

default switch setting is –130V.

 

 

 

 

 

 

 

 

DISABLED

Stops span power on the RLXIOR.

 

 

 

 

 

 

Pulse

Toggle

UNIT SWITCH

Selecting this option on the RLXIOR

UNIT SWITCH (Loop

Equalization**

 

 

creates a setting of 0–133 ft.

Extender chassis only)

 

 

 

 

NOT APPL (locked field

 

 

0–133 ft., 133–266 ft.,

The DS1 signal output provides standard

 

 

266–399 ft., 399–533 ft.,

DSX signal levels which can be

in Broadband chassis

 

 

or 533–655 ft.

compensated for various distances.

only)

 

 

 

 

 

LBO Setting**

Toggle

UNIT SWITCH

Selecting this option on the RLXIOR

UNIT SWITCH

 

 

 

creates a setting of 0.0 dB.

 

 

 

 

 

 

 

 

0.0 dB, 7.5 dB, 15.0 dB,

Sets the LBO in decibels.

 

 

 

or 22.5 dB

 

 

 

 

 

 

 

Programmable

Toggle

ENABLED

Enables response to programmable

DISABLED

Loopback

 

 

loopback codes.

 

 

 

 

 

 

 

 

DISABLED

Disables response to programmable

 

 

 

 

loopback codes.

 

 

 

 

 

 

NID Loopback**

Toggle

UNIT SWITCH

Disables loop-up response to NID arming

ENABLED

 

 

 

code. The loopback armed state transitions

 

 

 

 

to "Armed" when the NID arming code is

 

 

 

 

received.

 

 

 

 

 

 

 

 

ENABLED

Enables response to NID loopback codes.

 

 

 

 

 

 

 

 

DISABLED

Disables loop-up response to NID arming

 

 

 

 

code. The loopback armed state transitions

 

 

 

 

to "Armed" when the NID arming code is

 

 

 

 

received.

 

 

 

 

 

 

*Note: The RLXIOR configuration field default values shown in this manual are valid for systems with an MPU installed.

**Note: Although unit switch settings (Pulse Equalization, Span Power, NID Loopback, and LBO) are shown at the bottom of the configuration screen, none of the displays are meaningful for the RLXIOR. First, there are no on-board switches for Pulse Equalization, NID Loopback, and LBO. In addition, although the RLXIOR has an on-board Line Power switch, the Span Power unit switch setting display is locked at “DISABLED”.

(continued)

2-112

© 2000, ADC Telecommunications, Inc.