ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-534

Page 3 of 6

Table 534-1. RLX Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

Unit Service State

Toggle

IS (In-Service)

Places the unit in service and allows

OOS

 

 

 

equipment alarm reporting by the MPU.

 

 

 

 

Must be set to IS for reporting of equipment

 

 

 

 

alarms.

 

 

 

 

 

 

 

 

OOS (Out-Of-Service)

Removes unit from service and stops

 

 

 

 

equipment alarm reporting by the MPU.

 

 

 

 

 

 

T1 Provision

Toggle

YES

Brings up T1 default settings and allows

NO

 

 

 

configuration changes.

 

 

 

 

 

 

 

 

NO

No configuration changes allowed.

 

 

 

 

 

 

T1 Service State

Toggle

Leave this field at OOS at this time to avoid undesirable reporting of alarms. Set this field to IS

 

 

after completing the configuration of the remaining fields.

 

 

 

 

 

 

Line Code

Toggle

AUTO

When the RLX line code is set to AUTO,

AMI

 

 

 

the module senses the line code and

 

 

 

 

switches from AMI to B8ZS if an encoded

 

 

 

 

signal is detected. After switching to B8ZS,

 

 

 

 

the RLX stays locked in this line code until

 

 

 

 

an LOS is detected at both DS1 inputs.

 

 

 

 

 

 

 

 

AMI

Alternate Mark Inversion

 

 

 

 

 

 

 

 

B8ZS

Bipolar Eight-Zero Substitution

 

 

 

 

 

 

Framing Format

Toggle

AUTO

The system automatically detects,

AUTO

 

 

 

establishes, and displays “AUTO-NR-” and

 

 

 

 

the correct frame format (UNFRAMED, FT

 

 

 

 

ONLY, SF, or ESF).

 

 

 

 

 

 

 

 

UNFRAMED

Unframed data pattern

 

 

 

 

 

 

 

 

Ft ONLY

Used for SLC framing

 

 

 

 

 

 

 

 

SF

Super Frame

 

 

 

 

 

 

 

 

ESF

Extended Super Frame

 

 

 

 

 

 

Network DS1 Source

Toggle

NRZ

This tells the Craft that the network DS1

NRZ

 

 

 

source is at the backplane from the DS3

 

 

 

 

MUX.

 

 

 

 

 

 

 

 

BIPOLAR

This tells the Craft that the network DS1

 

 

 

 

source is at the bipolar DS1 interface. If

 

 

 

 

you select this option when you are in a

 

 

 

 

Broadband chassis, you will cut off the DS1

 

 

 

 

signal. This option is used in the Loop

 

 

 

 

Extender system. See Section 4 of this

 

 

 

 

manual for information about the Extender

 

 

 

 

Card.

 

 

 

 

 

 

 

 

 

 

(continued)

2-116

© 2000, ADC Telecommunications, Inc.