Table 534-1. RLX Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

BER Threshold

Toggle

Range of 10-3to 10-9

The average Bit Error Ratios of both the

10-7

 

 

 

incoming DS1 signals are monitored by the

 

 

 

 

RLX. By monitoring BERs, the RLX is

 

 

 

 

capable of triggering a minor alarm when

 

 

 

 

any of the monitored signals degrades

 

 

 

 

below the BER threshold level.

 

 

 

 

 

 

Span Power Setting*

Toggle

UNIT SWITCH†

Defaults to the span power hardware

Version A only: UNIT

 

 

 

configuration (DIP SWITCH) setting on the

SWITCH

 

 

 

Version A RLX only.

 

 

 

 

 

Version B only:

 

 

ENABLED

Allows span power on the Version B RLX.

 

 

 

To activate this selection, its jumper must

ENABLED

 

 

 

be set to either ±130V or –130V as shown

 

 

 

 

in Figure 525-2or

 

 

 

 

Figure 525-3.

 

 

 

 

 

 

 

 

DISABLED

Stops span power on the Version B RLX.

 

 

 

 

 

 

Pulse Equalization*

Fixed

Locked at NOT APPL.

 

 

 

 

 

 

 

LBO Setting*†

Toggle

UNIT SWITCH

Defaults to the hardware configuration (DIP

Version A only: UNIT

 

 

 

SWITCH) LBO setting on the Version A

SWITCH

 

 

 

RLX.

 

 

 

 

 

Version B only: 0.0 dB

 

 

0.0 dB, 7.5 dB, 15.0

Version A only: Overrides the hardware

 

 

dB, or 22.5 dB

configuration (DIP SWITCH) setting. Sets

 

 

 

 

the LBO in decibels.

 

 

 

 

Version B only: Sets the LBO in decibels.

 

 

 

 

 

 

Programmable

Toggle

ENABLED

Enables response to programmable

DISABLED

Loopback

 

 

loopback codes and overrides hardware

 

 

 

 

configuration settings.

 

 

 

 

 

 

 

 

DISABLED

Disables response to programmable

 

 

 

 

loopback codes and overrides hardware

 

 

 

 

configuration settings.

 

 

 

 

 

 