Page 2 of 6
|
|
| RLX CONFIGURATION |
|
|
|
| ||
|
| Group: 1 | Slot: 1 | Circuit ID: |
|
|
|
| |
Unit Equip State | : EQUIPPED |
|
| Pulse Equalization |
| : NOT APPL | |||
Unit Service State: OOS |
|
| LBO Setting |
| : UNIT SWITCH | ||||
T1 Provision | : YES |
|
| Programmable Loopback |
| : DISABLED | |||
T1 Service State | : OOS |
|
| NID Loopback |
| : UNIT SWITCH | |||
Line Code | : AUTO |
|
| Loopback Activation Code : 1101001111010011 | |||||
Framing Format | : AUTO |
|
| Loopback Deactivate Code : 1001001110010011 | |||||
Network DS1 Source: NRZ |
|
| Lpbk Timeout Disable Code: 1101010111010110 | ||||||
BER Threshold | : |
|
| Loopback Timeout Period | : 0 | minutes | |||
Span Power Setting: UNIT SWITCH | Network Keep Alive |
| : AIS |
|
| ||||
DS0 Channel | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 | ||||||||
(B = blocked) | . . . . . . . . . . . . . . . . . . . . . . . . | ||||||||
Unit Switch Settings: Pulse Equalization: NOT APPL | Span Power: DISABLED | ||||||||
|
|
|
|
| NID: DISABLED |
| LBO: 7.5 dB | ||
|
| Press |
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
|
| Figure |
|
|
| ||||
|
| Table |
|
|
|
| |||
|
|
|
|
|
|
|
| ||
FIELD | TYPE | OPTIONS |
| DESCRIPTION |
|
| DEFAULT | ||
Group | Toggle | 1, 2, 3, 4, 5, 6, or 7 |
| Specifies the module’s group number |
| 1 | |||
|
| (groups 6 and 7 are not |
| designated on the chassis. |
|
|
|
| |
|
| available in the 19- |
|
|
|
|
|
| |
|
| inch chassis) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Slot | Toggle | 1, 2, 3, or 4 |
|
| Specifies the module’s slot number |
| 1 | ||
|
|
|
|
| designated on the chassis. |
|
|
|
|
|
|
|
|
|
|
|
| ||
Circuit Identifier | Input | Enter up to 20 |
|
| This represents the customer’s circuit ID. |
| Blank | ||
|
| characters |
|
| The first and last characters must be alpha |
| |||
|
|
|
|
| or numeric; middle characters can be alpha, |
| |||
|
|
|
|
| numeric, or hyphens. |
|
|
|
|
|
|
|
|
|
|
|
| ||
Unit Equip State | Toggle | Equipped |
|
| Establishes communication with MPU. |
| UNEQUIPPED | ||
|
|
|
|
| Module must be set to EQUIPPED before |
| |||
|
|
|
|
| remaining selections are allowed. |
|
|
| |
|
|
|
|
|
|
|
|
| |
|
| Unequipped |
|
| No communication with MPU. |
|
|
| |
|
|
|
|
|
|
|
|
|
|
(continued)