RLX CONFIGURATION

 

 

 

 

 

 

Group: 1

Slot: 1

Circuit ID:

 

 

 

 

Unit Equip State

: EQUIPPED

 

 

Pulse Equalization

 

: NOT APPL

Unit Service State: OOS

 

 

LBO Setting

 

: UNIT SWITCH

T1 Provision

: YES

 

 

Programmable Loopback

 

: DISABLED

T1 Service State

: OOS

 

 

NID Loopback

 

: UNIT SWITCH

Line Code

: AUTO

 

 

Loopback Activation Code : 1101001111010011

Framing Format

: AUTO

 

 

Loopback Deactivate Code : 1001001110010011

Network DS1 Source: NRZ

 

 

Lpbk Timeout Disable Code: 1101010111010110

BER Threshold

: 1E-7

 

 

Loopback Timeout Period

: 0

minutes

Span Power Setting: UNIT SWITCH

Network Keep Alive

 

: AIS

 

 

DS0 Channel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

(B = blocked)

. . . . . . . . . . . . . . . . . . . . . . . .

Unit Switch Settings: Pulse Equalization: NOT APPL

Span Power: DISABLED

 

 

 

 

 

NID: DISABLED

 

LBO: 7.5 dB

 

 

Press CONTROL-A For Assistance

 

 

 

 

 

 

 

 

 

 

 

 

 

6127-C

 

 

Figure 534-1. RLX Configuration Screen

 

 

 

 

 

Table 534-1. RLX Configuration Fields

 

 

 

 

 

 

 

 

 

 

 

 

FIELD

TYPE

OPTIONS

 

DESCRIPTION

 

 

DEFAULT

Group

Toggle

1, 2, 3, 4, 5, 6, or 7

 

Specifies the module’s group number

 

1

 

 

(groups 6 and 7 are not

 

designated on the chassis.

 

 

 

 

 

 

available in the 19-

 

 

 

 

 

 

 

 

inch chassis)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slot

Toggle

1, 2, 3, or 4

 

 

Specifies the module’s slot number

 

1

 

 

 

 

 

designated on the chassis.

 

 

 

 

 

 

 

 

 

 

 

 

Circuit Identifier

Input

Enter up to 20

 

 

This represents the customer’s circuit ID.

 

Blank

 

 

characters

 

 

The first and last characters must be alpha

 

 

 

 

 

 

or numeric; middle characters can be alpha,

 

 

 

 

 

 

numeric, or hyphens.

 

 

 

 

 

 

 

 

 

 

 

 

Unit Equip State

Toggle

Equipped

 

 

Establishes communication with MPU.

 

UNEQUIPPED

 

 

 

 

 

Module must be set to EQUIPPED before

 

 

 

 

 

 

remaining selections are allowed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unequipped

 

 

No communication with MPU.

 

 

 

 

 

 

 

 

 

 

 

 

 

(continued)