ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-532

Page 2 of 3

DLX CONFIGURATION

Group:

5

 

Slot: 1

Unit Equip

State:

EQUIPPED

Unit Service

State:

IS

 

T1 Provision:

YES

 

T1 Service

State:

OOS

 

T1 Line Code:

AMI

 

Pulse Equalization:

0-133 FT.

T1 BER Threshold:

1E-7

 

Loopback Timeout Period:

0

minutes

Circuit ID:

 

 

Press CONTROL-A

For

Assistance

6126-C

Figure 532-1. DLX Configuration Screen

Table 532-1. DLX Configuration Fields

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

 

Group

Toggle

1, 2, 3, 4, 5, 6, or 7

Specifies the module’s group

1

 

 

 

 

number designated on the chassis.

 

 

 

 

 

 

 

 

Slot

Toggle

1, 2, 3, or 4

Specifies the module’s slot number

1

 

 

 

 

designated on the chassis. Refer to

 

 

 

 

 

TAD-106 (Access Identifier).

 

 

 

 

 

 

 

 

Unit Equip State

Toggle

Equipped

Establishes communication with

UNEQUIPPED

 

 

 

 

MPU. Module must be set to

 

 

 

 

 

EQUIPPED before remaining

 

 

 

 

 

selections are allowed.

 

 

 

 

 

 

 

 

 

 

Unequipped

No communication with MPU.

 

 

 

 

 

 

 

 

Unit Service State

Toggle

IS (In-Service)

Places the unit in service. This field

OOS

 

 

 

 

must be set to IS for reporting of

 

 

 

 

 

equipment alarms.

 

 

 

 

 

 

 

 

 

 

OOS (Out-Of-Service)

Removes unit from service and

 

 

 

 

 

stops equipment alarm reporting by

 

 

 

 

 

the MPU.

 

 

 

 

 

 

 

 

 

 

 

 

(continued)

2-107

© 2000, ADC Telecommunications, Inc.