Page 9 of 11
Table
DISPLAY | UNIT TYPE | DESCRIPTION |
Critical Alarm | Shelf | Critical Alarm shelf summary |
|
|
|
Major Alarm | Shelf | Major Alarm shelf summary |
|
|
|
Minor Alarm | Shelf | Minor Alarm shelf summary |
|
|
|
Remote Alarm | Shelf | Remote Alarm shelf summary |
|
|
|
Power Alarm | Shelf | Shelf Power A or B input failure (but not both) |
|
|
|
HSW Eqpt Alm | N/A | Not Applicable for this release |
|
|
|
HSP Eqpt Alm | N/A | N/A for this release |
|
|
|
HWS Fac Alm | N/A | N/A for this release |
|
|
|
HSP Fac Alm | N/A | N/A for this release |
|
|
|
MXW Eqpt Alm | DS3 MUX | Unit Fail, MPU COMM Fail, DS3 TX LOS, or (SISTER COMM Fail and not SISTER |
MXP Eqpt Alm |
| MPU COMM Fail) |
|
|
|
MXW Fac Alm | DS3 MUX | DS3 RX LOS, DS3 RX OOF, DS3 Loopback |
MXP Fac Alm |
|
|
|
|
|
Dxa L/R Alarm | ODS2 & QLX | DS2 Optical COMM Fail, DS2 Optical LOS, DS2 Optical OOF, DS2 Optical BER, |
|
| DS1 RX LOS, DS1 Loopback |
|
|
|
Dx L/R Alarm | HLX | DS1 RX LOS, HDSL LOSW, HDSL BER, HDSL SNR, DC Loop Continuity (if HLXR |
|
| is line powered), DS1 Loopback |
|
|
|
Dx L/R Alarm | RLX | DS1 RX LOS, DS1 RX LOF, DS1 Loopback |
|
|
|
Dx L/R Alarm | DLX | DS1 RX LOS, DS1 BER, DS1 Loopback |
|
|
|
HSKPx Rmt Alm | ODS2 & QLX | Slot number is |
|
|
|
|
| Slot number is |
|
|
|
|
| Slot number is |
|
|
|
|
| Slot number is |
|
|
|
HSKPx Rmt Alm | HLX | Remote Housekeeping Alarm A or B reported by an HLXR |
|
|
|
HSKPx Rmt Alm | RLX | N/A |
|
|
|
HSKPx Rmt Alm | DLX | N/A |
|
|
|
Lx Lcl Alarm | ODS2 & QLX | Unit Fail, MPU COMM Fail, Laser Degrade, DS1 TX LOS, or (SISTER COMM Fail |
|
| and not SISTER MPU COMM Fail) |
|
|
|
Lx Lcl Alarm | HLX | Unit Fail, MPU COMM Fail |
|
|
|
Lx Lcl Alarm | RLX | Unit Fail, MPU COMM Fail |
|
|
|
Lx Lcl Alarm | DLX | MPU COMM Fail |
|
|
|
Lx Rmt Alarm | ODS2 & QLX | Remote Unit Fail |
|
|
|
Lx Rmt Alarm | HLX | N/A |
|
|
|
Lx Rmt Alarm | RLX | N/A |
|
|
|
Lx Rmt Alarm | DLX | N/A |
|
|
|
a “x” represents the Soneplex chassis (shelf) slot number
© 2000, ADC Telecommunications, Inc.