ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

TAP-101

Page 3 of 13

The Circuit ID column displays the circuit identifier or facility name of the circuit in

trouble.

 

 

Reference:

DLP-532

DLX Configuration

Reference:

DLP-531

HLX Configuration

Reference:

DLP-530

ODS2 Module Configuration

Reference:

DLP-533

RLXIOR Configuration

Reference:

DLP-534

RLX Configuration

The Condition column displays the alarm condition present on the circuit. See Table 101-1for a listing of the possible alarm conditions.

The St (Status) column displays Critical (CR), Major (MJ), Minor (MN), or Event (EV), indicating the degree of the alarm. When an alarm clears, it is indicated on the Alarm History screen by the letters CL. Events are reported as they occur, but are not reported as cleared when they clear. Conditions configured as Not Reported are never reported at all.

The ACO column indicates whether the ACO is active (YES or NO) for the particular alarm. This column is found only on the Active Alarms screen.

7.Troubleshoot the problem, following local practices. Once the problem is located and corrected, the alarm is cleared and the LEDs return to their normal state.

Stop! You have completed this procedure.