Page 3 of 11
Table
MON TYPE | MEANING | LOCATION | DESCRIPTION |
CVL | Code Violation Line | NEND | Count of Bipolar Violations (BPV) and excessive |
|
|
| zeros (EXZ) in the DS1 signal. Note: The maximum |
|
|
| rate of indications across HDSL loops that the far end |
|
|
| can report is 166.7 BPV per second (10,000 per |
|
|
| minute). |
|
|
|
|
LOSS | Loss Of Signal | NEND | A second in which one or more Loss Of Signal defects |
| Second |
| occurred. |
|
|
|
|
ESL | Errored Second Line | NEND | A second in which there occurred one or more BPVs, |
|
|
| one or more EXZs, or one or more LOS defects. |
|
|
|
|
SESL | Severely Errored | NEND | A second in which more than some user specified |
| Second Line |
| value of CVLs or one or more LOS defects occurred. |
|
|
|
|
FCP | Failure Count Path | NEND | A count of Loss Of Frame (LOF) or Alarm Indication |
|
|
| Signal (AIS) failures within the interval. A failure is |
|
|
| counted when the failure condition transitions from |
|
|
| OFF to ON. Failure count is independent of the |
|
|
| duration (in seconds) of the failure condition. |
|
|
|
|
CVP | Code Violation Path | NEND | Count of (FE) Frame sync Errors in SF format or |
|
|
| count of CRC errors in ESF format. |
|
|
|
|
AISSP | AIS Second Path | NEND | A second containing one or more AIS defects. |
|
|
|
|
SASP | SEF/AIS Second Path | NEND | A second containing one or more AISSPs or one or |
|
|
| more SEF (Severely Errored Framing/OOF) defects. |
|
|
|
|
ESP | Errored Second Path | NEND | SF framing format: this is a second in which there |
|
|
| occurred one or more FE events, one or more SEF |
|
|
| defects, or one or more AIS defects. |
|
|
| ESF framing format: this is a second in which there |
|
|
| occurred one or more CVP errors, one or more SEF |
|
|
| defects, or one or more AIS defects. |
|
|
|
|
SESP | Severely Errored | NEND | SF framing format: this is a second in which there |
| Second Path |
| occurred more than eight FE events, one or more SEF |
|
|
| defects, or one or more AIS defects. |
|
|
| ESF framing format: this is a second in which there |
|
|
| occurred more than some user specified value of CVP |
|
|
| errors, one or more SEF defects, or one or more AIS |
|
|
| defects. |
|
|
|
|
Note: DS1 Path Parameters are collected at the HLXC for both directions, as shown in Figure
Note:
Note: For complete information on counts, refer to ANSI T1.231.
(continued)
© 2000, ADC Telecommunications, Inc.