Page 2 of 2
Do Items Below in the Order Listed | For Details Go To |
5.Momentarily press the LMPTST switch on the APU front panel and verify that all indicators light.
6. | Connect terminal equipment to Craft port on the front of the MPU. | |
7. | Log on to the Craft Interface. | |
8. | Clear Alarm History. | |
9. | Enter Target Identifier and set date and time now or during |
|
| provisioning (the | |
10. | Configure DS3 MUX as required. | |
11. | Configure ODS2 modules as required. | |
12. | Clean and mate fiber optic connectors and adapters as required. | |
13. | Connect the test equipment at both ends of the system and perform |
|
| an |
|
| module. |
14.If the Soneplex system being tested is equipped with protection modules:
| Execute Force/APS commands through the Craft Interface. | |
| Perform Manual (Force) Switch to Protect test on DS3 MUX |
|
| module. | |
| Perform APS test on DS3 MUX module. | |
| Perform Manual (Force) Switch to Protect Test on ODS2 module. | |
| Perform APS test on ODS2 module. | |
15. | Log off from the Craft Interface system. | |
16. | Complete assignment forms and update office records as required by |
|
| local procedures. |