ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

NTP-007

Page 1 of 1

MPU VERSION 5.3 SOFTWARE INSTALLATION AND TESTING PROCEDURES

Summary: This procedure is used to install MPU Version 5.3 software on an MPU. To perform this procedure, a host computer with VT-100 emulation and XMODEM file transfer capability is required. The application software requires 12 to 17 minutes to transfer depending on the type of host computer and the communication program used. MPU Version 5.3 software can only be downloaded to MPU Version 5.3 hardware.

Do Items Below in the Order Listed

For Details Go To

1.The following tools and equipment are required to perform this procedure:

Host computer system with VT-100 emulation

PC communication software with VT-100 emulation and with XMODEM file transfer capability

MPU Version 5.3 application software and download software (provided on diskette)

Straight through EIA-232 cable (for Craft port on MPU) or null-modem cable (for Port 2 or 3 on chassis back panel)

2.Connect the host computer to chassis port configured as the Craft

port. Turn the power on.

DLP-504

3.Insert the diskette with MPU Version 5.3 software and the database equalization software into the computer disk drive.

4.

Log on to the Craft Interface system.

DLP-526

5.

Download the MPU Version 5.3 software program and verify that

 

 

transfer is successfully completed.

DLP-551

6.

If no additional operations are required, log off from the Craft

 

 

Interface.

DLP-564

2-19

© 2000, ADC Telecommunications, Inc.