ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

NTP-008

Page 1 of 1

MPU CONFIGURATION DATA SAVE AND TRANSFER PROCEDURES

Summary: This procedure is used to save the configuration data from an installed MPU and then transfer it to another MPU. A host computer containing software that can emulate a VT-100 terminal and perform XMODEM file transfers is required.

Do Items Below in the Order Listed

For Details Go To

Note: Any configuration database from an MPU with Version 3.1 or later software can be downloaded to an MPU with Version 5 software. When downloading to an MPU that is not running Version 5 software, the MPU software version of the source MPU must match the software version of the destination MPU.

1.The following tools and equipment are required to perform this procedure:

Host computer system

VT-100 emulator program with XMODEM file transfer capability

MPU Version 5 application software.

MPU hardware with Boot Code Version 2.0 or later

Straight-through RS-232 cable (for Craft port on MPU) or null- modem cable (for Port 2 on chassis back panel)

2.Connect host computer to either the Craft port on the MPU or Port

 

2 on the chassis back panel. Turn host computer power on.

DLP-504

3.

Insert a diskette into the computer disk drive.

 

4.

Log on to the Craft Interface system.

DLP-526

5.

Perform the Configuration Upload command and transfer the

 

 

configuration data to the host computer.

DLP-554

6.

Replace the MPU or connect host computer to another MPU.

DLP-519

7.At the new MPU, repeat Steps 4 and 5, then select the Execute Configuration Data Download command and transfer the

configuration data from the host computer to the new MPU.

DLP-555

8. If additional operations are not required, log off the Craft Interface.

DLP-564

2-20

© 2000, ADC Telecommunications, Inc.