ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-506

Page 4 of 5

22.Repeat Steps 5 through 17 for the protection ODS2 module, then go to Step 23.

23.Repeat the entire procedure for each ODS2 module to be installed.

Stop! You have completed this procedure.

1 to 14 WORKING AND PROTECT ODS2 UNITS

(TOP ROW ONLY)

HSW HSP MXW MXP TAU 1-1 1-3 2-1 2-3 3-1 3-3 4-1 4-3 5-1 5-3 6-1 6-3 7-1 7-3 APU

RTAU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-2 1-4 2-2 2-4 3-2 3-4 4-2 4-4 5-2 5-4 6-2 6-4 7-2 7-4 MPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6184-B

 

DS3 MUX

 

 

 

RTAU

 

 

UNITS

 

 

MODULE

Figure 506-1. ODS2 Module Locations

Table 506-1. DS2 Signal Routing

DS2

DS1

GROUP-SLOT

GROUP-SLOT

SIGNAL

SIGNALS

NUMBER

NUMBER

 

 

WORKING UNIT

PROTECT UNIT

1

1 to 4

1-1

1-3

 

 

 

 

2

5 to 8

2-1

2-3

 

 

 

 

3

9 to 12

3-1

3-3

 

 

 

 

4

13 to 16

4-1

4-3

 

 

 

 

5

17 to 20

5-1

5-3

 

 

 

 

6

21 to 24

6-1

6-3

 

 

 

 

7

25 to 28

7-1

7-3

 

 

 

 

2-40