ADC MetroNID NTP Client or source, Power Consumption, Cooling, Redundant Power, Connectivity

Models: EtherNID MetroNID

1 12
Download 12 pages 50.97 Kb
Page 9
Image 9

9 / 0 8 • 1 0 7 0 3 3 A E   LoopStar® EtherNID– LoopStar® MetroNID

LoopStar® EtherNID™ – LoopStar® MetroNID™

ADC's network interface devices for Ethernet and IP networks

Specifications

Hardware & Performance

Pure Hardware Data-Path

• Inline transparent performance (all packet sizes):

Throughput:

wire-speed (1000 Mbps at 100% utilization)

Intrinsic Pass-through Traffic Latency:

< 3.3 μs

Intrinsic Pass-through Traffic Jitter:

< 0.1 μs

Intrinsic Latency for Intelligent Loopback:

< 0.8 μs

Intrinsic Jitter for Intelligent Loopback:

< 0.1 μs

High-accuracy, hardware-assisted performance measurements with 1μs resolution.

Integrated Management

• SNMP v1, v2c

• Radius Authentication

• Secure Web GUI via SSL

• Secure CLI via SSH

• Management VLAN

• 802.3ah EFM OAM

• Configuration import/export

FTP, TFTP, HTTP, HTTPS

• NTP Client (or source)

Remote and Local Syslog

• DNS Client

• DHCP Client

In-band remote management over the Ethernet customer line via network & client-side interface

Local Management craft port: 10/100BaseT RJ-45 connector

Serial RS-232 Management port: RJ-45 connector

Zero-Touch provisioning to OSS systems & EchoVault™ SLA EMS

Redundant Power, Connectivity & Timing

 

 

Power:

External AC/DC adapter (120-240Vac auto-sensing, 50-60Hz), 5VDC input to unit

 

 

Dual (A/B) -48Vdc Central Office Supply inputs

 

Power Consumption:

5-8 watts

 

 

Cooling:

Convection cooled (no fans)

 

Redundant Power:

Transparent fail-over bypass on electrical-to-electrical models

 

Connectivity:

Dual Protected Uplink allows two redundant connections on the network side for

 

 

increased reliability(1)

 

GPS:

Optional embedded GPS with front-panel SMA input(1)

Physical Specifications

 

 

 

Dimensions (H x W x D):

1.60” x 5.34” x 5.80” (4.06 cm x 13.56 cm x 14.73cm)

 

Weight:

625 g or 1.37 lb

 

MTBF:

52-66 years (at 25 degree C ambient)

 

Mounting Options:

Desktop, Wall-mount, Rack-mount:1 or 2 units side-by-side in 1U

 

 

EtherSHELF™: High density, 12-unit, 19” Central Office shelf in 4U

 

 

(23” adapter available)

Regulatory and Certification

 

 

 

• IEC 60950

• NEBS Level 3

 

• FCC Part 15 Class A

• MEF9 Service Certification

 

• Industry Canada CS-03

• MEF14 Traffic Management

 

• CE Mark

 

 

Environmental

 

 

 

Standard operating temperature:

-5º to +65°C (23º to 149ºF)

 

Hardened operating temperature (-H):

-40º to +65°C (-40º to 149ºF)

Storage temperature:

 

-40º to +70°C (-40º to 149ºF)

Operating/storage humidity:

 

5-95 %RH non-condensing

(1) Available on MetroNID™ models only

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

9

Page 9
Image 9
ADC MetroNID NTP Client or source, Power Consumption, Cooling, Redundant Power, Connectivity, Weight, Mounting Options