Issue 1, November 1996
CLINCH
NUT
CONNECTOR
BODY
BUSHING
SPLIT
RING
COMPRESSION
NUT
0SP
CABLE
HUBBELL
CONNECTOR8993-A
(ASSEMBLED)
Figure 6. Hubbell Connector Kit
Cable Clamp Kits
2.07The cable clamp kits (Figures 7 and 8) are installed
Note: The breakout lengths of the OSP cable fibers should be long enough to extend 2.5 times around the radius limiters that surround the splice tray.
1. Mount the selected cable clamp mounting plate (either high or low) using two #4 mounting screws into the rear panel of the wall box per Figure 7 or Figure 8.
2.Select a grommet which (when placed around the cable), has a gap within the range of nearly zero to 0.30 inch (0 to 8 mm). If the outer diameter of the cable is 0.7 to 0.8 inch (1.78 to 2.03 cm), no grommet is required.
3.Assemble the cable clamp components as shown in Figure 7 or 8: secure the cable and grommet (if used) between the two cable clamp yokes, then place the clamp plate over the outer yoke and secure the yokes and cable to the mounting plate with two long screws. Be sure the cable sheath extends approximately 0.75 inch (1.9 cm) beyond the cable clamp.
4.Repeat steps 1 through 3 as necessary to install additional cable clamp kits.
Page 8