9 / 0 8 • 1 0 2 0 9 7 A E   TrueNet® CopperTen® Termination Block

9 / 0 8 • 1 0 2 0 9 7 A E   TrueNet® CopperTen® Termination Block

TrueNet®

CopperTen® Termination Block

Specifications

MECHANICAL

 

Wire range for solid and stranded copper conductors:

0.4 mm to 0.65 mm (26 to 22 AWG)*

Wire insulation diameter range (PE, PVC):

0.7 mm to 1.4 mm

Number of wire terminations:

> 100

Wire insertion force (0.5 mm conductor diameter):

6 N

Wire pull out force, radial (0.5 mm conductor diameter):

5 N

Wire pull out force, axial (0.5 mm conductor diameter):

35 N

Number of patching cycles:

Modules: up to 750

 

Patch Plugs: up to 200

ELECTRICAL

 

Transmission, performance and reliability:

TIA-568.B.2-10 standards

Voltage/current rating at 25 ºC (77 ºF) ambient:

150 VAC at 2.5A max

Insulation resistance:

> 50,000 M at 500 VDC

ENVIRONMENTAL AND SAFETY

 

Safety compliance:

UL 1863

Flammability rating of plastic housing:

UL 94-VO

Environment for use:

Indoors or in dry enclosure

*Should there be a requirement to terminate cables other than 10 Gigabit cable, a maximum of 2 equal diameter solid conductors only, of up to 0.5 mm conductor diameter can be terminated per slot. Only 1 conductor of stranded wires per slot can be terminated. If any conductors >0.5 mm diameter have been terminated, reversal to smaller conductors is no longer possible.