9 / 0 7 • 1 0 3 6 9 3 A E FlexWaveWMX 3000

FlexWaveWMX 3000

WiMAX Single-sector Base Station

Specifications

RADIO AND SYSTEM SPECIFICATIONS

 

 

Compliance:

IEEE 802.16-2004 (3.5T1, 3.5T2), ETSI HiperMAN

Duplexing Mode, PHY:

TDD, OFDM 256 FFT

 

Frequency:

3.3 – 3.4 GHz, 3.4 – 3.6 GHz, 5.725 – 5.925 GHz

 

Future: 3.6 – 3.8 GHz, 5.15 – 5.35 GHZ, 5.475

 

– 5.725 GHz

 

Channel Bandwidth:

1.75 MHz, 3 Mhz, 3.5 MHz, 5.0 Mhz, 5.5 MHz,

 

and 7.0 MHz,

 

Step Size:

250 KHz

 

Radio Output Power:

17 dBm, 20 dBm, 30 dBm options

Receiver Sensitivity:

-95.1 dBm

 

Modulation:

BPSK, QPSK, 16QAM, 64QAM

Forward Error Correction:

Convolution coding 1/2, 2/3, 3/4

IP Networking Features/Options

 

 

IP Version:

IPV4 (RFC 791)

 

Bridging Mode:

IEEE 802.3d

 

Routing:

RIP V2, OSPF (future)

 

VLANs:

IEEE 802.1 P/Q

 

Security/Encryption

 

 

Authentication:

X.509 based authentication

 

Encryption:

3DES, AES CCM 128, 1024

 

Multi-Service/Multi-User Support

 

 

Traffic Classification:

MAC DA/SA, 802.1 P/Q, IP SA/DA, IP Protection, IP TOS,

 

TCP/UDP Port

 

Scheduling/QoS:

UGS, rtPS, nrtPS, BE, CIR, MIR

Max # Sectors:

single

 

Active Connected Subscriber Units:

512 per sector

 

Uni-directional Service Flows:

up to 7168 per sector

 

Physical Interfaces

 

 

RF Sectors, IF Port:

1 x IF Port for connection to BSR

 

(Type-F, Female, 75 Ohm)

 

Backhaul:

1 x 10/100 BT (RJ45)

 

Management:

RS-232 (DB9)

 

External clock, Synchronization:

10 MHz Clock (BNC) /1 Hz Sync (BNC)

Management

 

 

Remote Management and Monitoring:

WaveCenter EMS Pro, CLI (Telnet), SNMP

Local Management and Monitoring:

CLI (RS 232)

 

Provisioning:

Centralized using WaveCenter EMS Pro (SNMP)

SNMP:

MIB II (RFC 1213), Enterprise MIB;

 

SNMP V2, IEEE 802.16f MIB

 

Mechanical

 

 

Indoor Unit Dimensions (W*H*D)/weight:

42.0 x 4.2 x 27.0 cm / 16.5" x 1.65" x 10.6"/5.5 kg

 

(12 lbs.)

 

Outdoor Unit (W*H*D)/weight:

29.8 x 7.0 x 29.8 cm / 11.75" x 2.75" x 11.75"/4.5 kg

 

(10 lbs.)

 

IDU-ODU Distance:

up to 250 m

 

Electrical

 

 

Input DC Voltage:

DC 40 – 60V

 

Input AC Voltage:

85 VAC – 265 VAC

 

Max Power Consumption:

70 W

 

Environmental

Indoor

Outdoor

Weather Protection:

na

IP65/NEMA-4

Operation Temperature:

0° to 40° C

- 35° to 60° C

Humidity:

10 - 90%, non-condensing

0 - 95%, non-condensing

RoHS Compliance:

yes

yes

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

3

Page 3
Image 3