ADCP-50-304 • Issue 19 • June 1999 • Section 6: Installation

DCE/DTE BERG

POST FOR DSR

JUMPER

BERG

DIP

SOCKET

STRAP

 

RSP

CMD

SEL

CTL

U3

U1

DTE

U5

U2

DCE

 

 

U4

U6

 

PROGRAMMING

PLUG 1635-A

Figure 6-2. Data Converter Module

1.6Control Module DIP Switch Settings

When PatchSwitch equipment is configured for serial remote control, the chassis address must be selected on each control module. For dc pulse control, the chassis address is ignored. Each CM contains a four-position DIP switch to identify its chassis address. Bit positions 1 through 4 on the DIP switch are set to an identifying address assigned to that chassis during the installation of the PS chassis system.

Caution: Make certain that each chassis on a communications channel is assigned a different (unique) identifying address in the range of 0 through 15 (0002 through 11112).

Page 6-4

© 1999, ADC Telecommunications, Inc.