6.20 SPKxx Format
When a remote control device selects a PS chassis by issuing a “SPKxx” command, and then requests status by issuing a “UP#” command, the CM responds with the condensed status format. The condensed status format is a string of eight hexadecimal digits representing the switch positions and alarm conditions for all 16 module slots contained in the selected PS chassis. The “SPKxx” command is used by the RCU.
Each digit displayed is a hexadecimal code representing the switch position or alarm condition for four PS modules. As shown in the example of Table
The second, third and fourth hexadecimal digits (616, A16 and 316) are decoded to their binary equivalents which are “0110”, “1010”, and “00l1”, respectively. These 12 bits are assigned to module addresses 11 through 0 (least significant). In this example (56A3)16, modules 15, 13, 11, 8 6, 4, 3, and 2 are in the “A” switch position and modules 14, l2, 10, 9, 7, 5, l, and 0 are in the “B” switch position.
The alarm status for the same l6 PS modules is displayed in the last four hexadecimal digits “10l0”. The alarm status code is read in the same manner as the switch status code. The fifth hexadecimal digit “1” is decoded to it's binary equivalent which is “000l”. These four binary digits (bits) are assigned to module addresses 15 (most significant) through 12. A “0” bit indicates a no alarm condition for the module and conversely, a “l” bit indicates the module detected an alarm.
The second, third and fourth hexadecimal digits (016, 116 and 016) are decoded to their binary equivalents which are “0000”, “000l”, and “0000”, respectively. These twelve bits are assigned to module addresses l l through 0 (least significant). Therefore, in this example (1010)16, modules l2 and 4 indicate an alarm condition is detected and the remaining modules indicate no alarm is detected.
Table
Page