Addlogix RPS14 Replacing the mains fuse, Technical specification, On The Unit, DC Voltage Rail

Models: RPS14

1 8
Download 8 pages 48.25 Kb
Page 8
Image 8
Replacing the mains fuse

Replacing the mains fuse

The AC mains fuse is located on the rear of the RPS14 unit next to the AC mains connector. In the event of a mains surge or under-rated fuse value, the fuse will rupture. Switch off the power supply and remove the mains lead plug from the “MAINS INPUT” socket on the rear of the unit. Check the fuse and replace if necessary. In the event of repeated failure of the mains fuse, consult your Allen & Heath service agent.

In the unlikely event of an internal DC rail fuse failure, consult your Allen & Heath service agent or Allen & Heath technical support.

TO AVOID THE RISK OF FIRE REPLACE FUSE WITH THE CORRECT TYPE ONLY, AS INDICATED

ON THE UNIT.

 

 

 

 

 

 

 

AC~ mains input voltage

Fuse type

A&H Part No.

 

 

 

 

 

100V – 120V ± 10%

T 10A 250V 20mm

AL3455

 

220V – 240V ± 10%

T 8A 250V 20mm

AL0487

 

 

 

 

Technical specification

Mains Input Voltage Range:

Internally wired for region:

 

 

 

100V +/- 10%

50/60Hz

 

 

 

120V +/- 10%

50/60Hz

 

 

 

220V +/- 10%

50/60Hz

 

 

 

240V +/- 10%

50/60Hz

 

 

 

Note: Contact Allen & Heath if your local mains voltage is not shown above.

Power consumption (max.)

650W

 

 

 

Mains Fuse:

100/120V

T10A 250V 20mm

A&H Part no:

AL3455

 

220/240V

T8A 250V 20mm

A&H Part no:

AL0487

Internal Fuses:

 

 

 

 

PCB Ident

Fuse type

 

 

F1 (+17.5V)

T 16A 250V 20mm

A&H Part no:

AL8154

F2 (-17.5V)

T 16A 250V 20mm

A&H Part no:

AL8154

F3 (+48V)

T 1.6A 250V 20mm

A&H Part no:

AL0466

F4 (+12V)

T 6.3A 250V 20mm

A&H Part no:

AL0395

DC Outputs:

 

 

 

 

DC Voltage Rail

Output Current

 

 

+17 VOLTS

 

8A Max.

 

 

-17 VOLTS

 

8A Max.

 

 

+12 VOLTS

 

4A Max.

 

 

+48 VOLTS

 

500mA Max.

 

 

Overall Dimensions:

 

 

 

 

Front Panel:

 

483mm x 88mm

19 inch 2U

 

Chassis

 

443mm x 88mm

17.4 inches

 

Height including feet:

 

92mm

3.6 inches

 

Depth:

 

328mm

12.9 inches

 

Weight:

 

12kg

26.4 lbs

 

Cable Assemblies:

 

 

 

 

Assembly

Description

A&H Part no:

 

DC cable

2.9m power supply to console cable assembly

002-583

 

 

DC LINK cable

0.75m backup supply to main supply cable assembly

002-584

 

8

 

 

RPS14 User Guide

Page 8
Image 8
Addlogix RPS14 manual Replacing the mains fuse, Technical specification, On The Unit, DC Voltage Rail, Output Current