BZS Switch (SW1:1):

The BZ switch is used to silence the audible alarm buzzer. The OFF position permits the audible alarm, and the ON position silences the audible alarm. The BZ switch has immediate effect.

EZ Switch (SW1:2):

The EZ (spare) switch inhibits spares when ON. When in the OFF position, all individual drives (not defined as members of an array) are considered spare. Should a RAID become degraded, when the EZ switch is in the OFF position a spare drive will be used automatically to rebuild the RAID, if present. EZ mode is determined when the unit is powered up. Changing the switch will have no effect until the unit has been re-powered.

RAID Mode Switches M2, M1, M0 (SW1:3 – SW1-5)

The RAID Mode switches define what type of RAID will be initialized when the unit is powered up while the RAID Mode button is held down. Each type of RAID has different properties and requirements, as follows:

 

Raid Mode

BZS1

EZ

M2

 

M1

M0

 

JBOD (Individual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

drives)

 

OFF

OFF2

OFF

 

OFF

OFF

 

 

 

 

* FACTORY DEFAULT

 

 

 

 

 

 

 

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

OFF

ON3

ON

 

ON

ON

 

1 or 10

OFF

OFF

ON

 

ON

OFF

3

 

OFF

OFF

ON

 

ON

OFF

5

 

OFF

OFF

OFF

 

ON

OFF

 

CLONE

OFF

OFF

OFF

 

ON

ON

 

LARGE

OFF

ON3

ON

 

OFF

ON

1 Audible alarm is recommended at all times.

2 EZ mode has no effect in JBOD mode.

3 Disabling EZ for RAID 0 and LARGE is strongly recommended.