NOTE

Gasket binder material used in this heater assembly will temporarily emit an odor and/or vapor. This condi- tion will clear up in approximately 20 minutes and thereafter will not reoccur. Refer to Chapter 2 for ventilation.

1. OPERATING SAFETY INSTRUCTIONS

2. HEATER STARTUP

WARNING: When used without fresh air, heater may

give off CARBON MONOXIDE, an odorless poison- ous gas. OPEN WINDOW AN INCH OR TWO FOR FRESH AIR WHEN USING HEATER.

WARNING: This heater is equipped with a PILOT

LIGHT SAFETY SYSTEM. DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM.

WARNING: If heater shuts off, do not relight until you

provide fresh air. Open door for 5 minutes. If heater keeps shutting off, have it serviced. Keep burner and control clean.

WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. Early signs of carbon monoxide poisoning resemble the flu with headache, dizziness and/or nausea. If you have these signs, heater may not be working properly. Get fresh air at once! Have heater serviced.

WARNING: DO NOT USE MATCH OR OTHER FLAME FOR LEAK TESTING.

WARNING: During heater startup ensure that building is well ventilated.

A.Open the gas supply valve or valves.

B.Set the thermostat to the OFF position. See Figure 8.

FIGURE 8. THERMOSTAT CONTROLS

CAUTION: If the infra-red color of the grid becomes

 

dull when the building furnace is operating, consult

C. If the manual gas control knob on the gas valve is

gas supplier on correct gas supply piping sizes.

not in the OFF position, partially depress the knob

CAUTION: This heater is for indoor installation only!

and rotate to the OFF position. See Figure 9.

 

PRESSURE

MANUAL GAS

REGULATOR

CONTROL KNOB

ADJUSTMENT

STANDARD

PRESSURE

REGULATOR

WRENCH

 

PILOT GAS OUTLET

BOSS

 

(PRESSURE TAPPING

 

 

DIRECTLY BENEATH)

 

GAS

 

 

INLET

 

 

PILOTSTAT

PILOT FLOW ADJUSTING SCREW

 

(BENEATH COVER SCREW)

 

POWER UNIT

 

 

Figure 9. Gas Valve Components

Model # MH25NG/LP

HS25NG/LP

10 Installation instructions and Owner’s Manual