MAINTENANCE

!WARNING: ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS.

BELT REPLACEMENT

1.Turn off all switches and unplug machine.

2.Remove recovery tank and brush.

3.Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4.Loosen the (4) screws that hold the brush motor in place and slide motor forward to release tension in belt.

5.Remove the (2) screws that fasten the vacuum shoe links (p/n 05016) to the brush housing.

6.Remove the (3) screws that fasten the side plate (p/n 62759) to the brush housing to remove belt. NOTE: All components associated with driving the brush will come out with the side plate.

7.Reverse process to install belt.

86249420

PRV NO. 62759

86287330

PRV NO. 05016

ADMIRAL 86038230 03/16/07

4-4