An optional feature of your system allows you to assign a certain number of valid
uses to User Code 6. After the code has been used the programmed amount of times,
it automatically becomes disabled. This code may be assigned to a maintenance
person, a maid, or anyone who you would like to be able to arm and disarm the
system for a selected number of times without having to give out your regular code.
After the uses have expired,
the
code will cease to function. It can be re-enabled by
programming in another number indicating how many times
that
it can be used. It
will not be necessary to re-program the actual code unless changing the code itself
is desired.
1.
2.
3.
4.
5.
6.
7.
8.
9.
The system must be disarmed.
Press key 9 and hold for three seconds. The control station will beep three times.
Enter the Master User Code. The control station will beep two times. The
READY and ARMED indicators will blink alternately and the other eight
indicators will blink in sequence with each other when the programming mode
is successfully entered (see note
*).
Press key 6, then
#
to instruct the control
that
you wish to program the desired
code sequence for User Code 6. The control station will beep three times.
Enter the desired four digit code sequence. After the fourth digit is entered, the
control station will emit one short beep followed by one long beep then the
system will exit the programming mode automatically.
Repeat step 2 to re-enter
the
programming mode.
Press keys 7 plus # to instruct the control that you wish to program the number
of valid uses for User Code 6. The control station will beep two times.
Enter the number of uses desired,
1
-
255, then press the
* “key. The control
station will beep two times.
Press the
*
key twice to exit the programming mode.
Note:
The temporary code may perform ail oft
he
functfons of your regular
User Codes. Only the Master User
Code
(Coda
1) will
permit entry into the
programming mode of operation. Remote Ptogrammlng Is not avaltable
In
U.L. Listed Systems.
+
NOTE REGARDING REMOTE PROGRAMMING:
If the ALARM indicator lightssteady after entering the programming mode,
your Installer has enabled the Remote Programming optlon. This feature
enables the installing company (or someone assigned by them) to re-
motely
service
and control your system.