ADTRAN 1000 239 HRE Switch, Powering Options, Warranty, Compliance, ADTRAN 239 REPEATER HOUSINGS

Models: 1000 239 HRE

1 2
Download 2 pages 27.31 Kb
Page 2
Image 2
TURNUP GUIDE

TURNUP GUIDE

PRICING AND AVAILABILITY 800.827.0807 TECHNICAL SUPPORT 800.726.8663 RETURN FOR REPAIR 256.963.8722 www.adtran.com 61179513L1-22A

POWERING OPTIONS

Figure 1

The ICOT will power the entire Total Access 1000 System. When an HRE is used to extend the range of the POTS circuits, a second ICOT is used to provide auxiliary span power to the system through additional copper pairs. (See Figure 1). The Total Access 1000 system continues to receive span power through the HDSL loops. The second ICOT is only needed for its span powering capacity. No circuit information can be accessed from it. No DSX-1 connections are necessary. The loop will not train, and it will always show an alarm condition. Applications using only U-BR1Tes do not require an additional ICOT.

WARRANTY

 

 

Central Office

 

Customer Premises

 

 

 

 

750

 

T1

TRDDB

2391221045L1HRE

 

Switch

 

 

TR-08

 

NET

 

CUSTOM

D(Y)SLR(GCUSTL)

 

 

 

 

 

 

SF

TE190349LECOM

HRE

Phone

 

Total Reach

 

or

 

 

 

ICOT

 

 

 

ESF

 

Total Access 1000 RT

 

 

Modules

 

System

 

 

TRDDB

Auxiliary

 

 

 

 

 

 

 

CUSTOM

Power

 

 

 

 

 

 

 

TE190349LECOM

Pairs

 

 

 

Total Reach

 

ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. USA and Canadian customer Faxback: (877) 457-5007, Document 414.

COMPLIANCE

The 239 HRE complies with the requirements covered under UL 60950 and is intended to be installed in an enclosure with an Installation Code (IC) of “B” or “E.” Ensure chassis ground is properly connected.

Code

Input

Output

Power Code (PC)

C

C

Telecommunication Code (TC)

X

X

Installation Code (IC)

A

ADTRAN 239 REPEATER HOUSINGS

PART #
Description
HRE Capacity
CLEI Code*
Material

1150027L1

4-slot Air Stub

4

DDMOABA1MA

Stainless Steel

1150027L2

4-slot Gel Stub

4

DDMOBBA1MA

Stainless Steel

1152010L3

2-slot Gel Stub

2

DDMOBAE1RA

Valox Plastic

1152010L4

2-slot Air Stub

2

DDMOAAE1RA

Valox Plastic

1150057L1

4-slot Air Stub

4

DDMODA01RA

Stainless Steel

1150057L2

4-slot Gel Stub

4

DDMOCA01RA

Stainless Steel

1150058L1

8-slot Air Stub

6

DDMOEE01RA

Stainless Steel

1150058L2

8-slot Gel Stub

6

DDMOFE01RA

Stainless Steel

1190816L1

16-slot Air Stub

16

DDMOES01RA

Stainless Steel

1190816L2

16-slot Gel Stub

16

DDMOFS01RA

Stainless Steel

HRE 239 DEPLOYMENT IN OTHER HOUSINGS

Company

Description

HRE Capacity

Material

 

 

Above Ground

Below Ground

 

AT&T, Keptel, ABACON

25-slot

12

16**

Polymer

SPC

6-slot Air Stub

5

6

Stainless Steel

SPC

6-slot Gel Stub

5

6

Stainless Steel

 

 

 

 

 

SPC

8-slot Air Stub

7

8

Stainless Steel

SPC

8-slot Gel Stub

7

8

Stainless Steel

Keptel

8-slot Air Stub

8

8

Valox Plastic

AT&T, Keptel

12-slot Air Stub

6

N/A

Polymer

Lucent

100-slot

42

N/A

Steel

 

 

 

 

 

HOUSING DIAGRAMS

ADTRAN 8-slot

AT&T/Keptel/ABACON

Above Ground

Above Ground

Below Ground

 

 

5

 

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

4

 

 

 

 

 

 

 

 

1, 3, 5, 7, 8,10, 12, 14, 15,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16, 18, 19, 20, 22, 24, 25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1, 4, 7, 8, 11, 14, 15,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17, 19, 20, 23, 25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPC 6-slot

 

SPC 8-slot

 

 

 

 

 

 

 

 

AT&T/Keptel

Above Ground

Above Ground

 

 

 

 

 

 

 

 

Above Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

6

 

5

 

 

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* TIRKS function code for all cases is HTURENN

 

 

 

 

1, 3, 5, 7, 9, 11

 

 

 

**16 units can be loaded inside the 819 housing for all below ground mounting orientations. if the 819 housing is mounted specifically in the vertical, stub down direction, 18 units can be loaded in slots 1, 3, 5, 7, 8, 10, 12, 13, 14, 15, 17, 18, 19, 20, 21, 22, 24, 25.

† Vented

Pressurized

Lucent 100 Slot Above Ground

Filled:

Shelf 1: 1, 3, 5, 7, 9, 11

Shelf 2: 1, 3, 5, 7, 9, 11, 14, 16, 18, 20, 22, 24

Shelf 3: 1, 3, 5, 7, 9, 11, 14, 16, 18, 20, 22, 24

Shelf 4: 1, 3, 5, 7, 9, 11, 14, 16, 18, 20, 22, 24

Page 2
Image 2
ADTRAN 1000 239 HRE Switch, Powering Options, Warranty, Compliance, ADTRAN 239 REPEATER HOUSINGS, Housing Diagrams, Code