Chapter 3. Operation

QUAD FXS VOICE MODULE MENU OPTIONS

Figure 3-1 shows the menu options available for the Quad FXS Voice Module.

The following sections describe these options.

 

Figure 3-1. Quad FXS Voice Module Menu Options

PRT

Identifies the port involved.

MODE

Options are given below.

LOOP START

Sets the port to use FXS loop start signalling on the T-span and loop start

 

supervision on the analog 2-wire interface.

GROUND START

Sets the port to use FXS ground start signalling on the T-span and ground

 

start supervision on the analog 2-wire interface.

TR08 SINGLE

Sets the port to use Single Party Channel Unit signalling on the T-span (as

 

defined by TR-TSY-000008) and loop start supervision on the analog 2-wire

 

interface.

TR08 UVG

Sets the port to use UniversalVoice Grade signalling on the T-span (as

 

defined by TR-TSY-000008) and either loop start or ground start supervi-

 

sion on the analog 2-wire interface.

DPO

Sets the port to use Dial Pulse signalling to originate dialed numbers.

TANDEM (E&M)

Sets the port to use E&M signalling on the T-span and either loop start or

 

ground start supervision on the analog 2-wire interface. See the Tandem sub-

 

menus for more information.

61175408L1

Quad FXS Voice Module User Manual

3-3

Page 17
Image 17
ADTRAN 1175408L1 user manual Quad FXS Voice Module Menu Options