ADTRAN 4303 PLUS specifications FRONT PANEL LEDs, Description, Specifications, Alarm Relays, Temp

Models: 4303 PLUS

1 2
Download 2 pages 46.85 Kb
Page 1
Image 1
TOTAL ACCESS 4303 PLUS DC POWER SUPPLY

TOTAL ACCESS 4303 PLUS DC POWER SUPPLY

JOBAID

61202335L1-22A

0401

DC SUPPLY

CLEI:SUPPLYSL OCDBC_ _

DC1202335L1PLUSTEMPPOWER

#61202335L1-22A#

FRONT PANEL LEDs

POWER

Off

Both –48 VDC fuses blown, power not supplied to the shelf,

 

 

or incorrect polarity on the voltage supplied to the shelf

 

Green

Power supplied is the correct voltage and polarity; backplane

 

 

and hot insertion voltages correct

 

Amber

–48 VDC input and hot insertion voltage present; no back-

 

 

plane voltage

 

Red

–48 VDC input present; no backplane voltage and no hot

 

 

insertion voltage

TEMP

Off

Normal

 

Red

Over-temperature condition

DESCRIPTION

The Total Access® 4303 Plus DC Power Supply is a removable assembly that provides the voltages necessary for proper system operation. The unit features LEDs for over- temperature and DC output, an input fuse, and the ability to be hot-swapped when used with another DC supply in the same chassis. The supply interfaces to the Total Access backplane through a 48-pin connector. The unit accepts one or two –48 VDC inputs from the backplane and supplies –48 VDC fused output for use with external input logic, +5 VDC as hot insertion bias voltage for modules, and +2.1 VDC for back- plane termination. In addition, the Total Access 4303 Plus DC Supply provides alarm relay ouputs when installed in slot PS-A.

The following features are supported on the Total Access 4303 Plus DC Power Supply:

Thermal limit indicator with open collector output

DC status indicator on the 2.1 and 5 volt outputs with open collector output

Short circuit protection

Compatible with existing Total Access DC Power Supplies (P/N 1200335L1)

SPECIFICATIONS

Specifications

Input Voltage

–42 VDC to –56 VDC

Operating Temperature

–40°C to +65°C

Storage Temperature

–40°C to +85°C

Relative Humidity

Up to 95% noncondensing

Over Temperature Indication

90°C ±5%

–48 VDC Short Circuit Protection

Fused 1-amp slow blow

Backplane Voltage Short Circuit Protection

Self-mending

Compliance

FCC Part 15, UL 60950, NEBS Level III,

 

GR-1089-CORE

ALARM RELAYS

There are eight alarm relays that provide normally open or normally closed contacts for each of the following alarms:

Visual Critical

Visual Major

Visual Minor

Audible Critical

Audible Major

Audible Minor

Auxiliary 1

Auxiliary 2

POWER SUPPLY 48 PIN CONNECTOR PINOUT

Pin #Row A SignalRow B SignalRow C Signal

1

AUD_CRIT_NO

AUD_CRIT_COM

AUD_CRIT_NC

2

AUD_MAJ_NO

AUD_MAJ_COM

AUD_MAJ_NC

3

AUD_MIN_NO

AUD_MIN_COM

AUD_MIN_NC

4

VIS_CRIT_NO

VIS_CRIT_COM

VIS_CRIT_NC

5

VIS_MAJ_NO

VIS_MAJ_COM

VIS_MAJ_NC

6

VIS_MIN_NO

VIS_MIN_COM

VIS_MIN_NC

7

AUX1_RLY_NO

AUX1_RLY_COM

AUX1_RLY_NC

8

AUX2_RLY_NO

AUX2_RLY_COM

AUX2_RLY_NC

9

–48V_A

PS_OK

PS_TEMP

10

–48V_B

2.1V

PS_PRESENT

11

2.1V

2.1V

2.1V

12

–48V_AB_RTN

2.1V

VCC

13

GND

GND

GND

14

GND

GND

PSRLY_CLK

15

GND

PSRLY_LOAD

PSRLY_DATAIN

16

FR_GND

–48V

PSRLY_DATAOUT