TURNUP STEPS

To install the Total Access 4303 Plus DC Power Supply, perform the following steps:

1

2

3

4

5

6

After unpacking the Total Access 4303 Plus DC Power Supply, inspect it for damage. If damage is found, file a claim with the carrier and then contact ADTRAN® Customer Service.

Pull the ejector tab on the bottom of the Total Access 4303 Plus DC Power Supply into the down position.

Hold the Total Access 4303 Plus DC Power Supply by the front panel while supporting the bottom edge of the module and align the module edge with the guide groove for slot PS-Aor PS-Bin the chassis. If using only one Total Access Plus DC Power Supply module, insert the module in slot PS-Ain order to use the alarm relay outputs.

Gently but firmly push the module into the selected slot. Simultaneous thumb pressure at the top (above the POWER LED) and at the bottom (below the electrostatic caution symbol) of the module will ensure a good seat of the module pins into the backplane connector.

Apply power to the shelf and verify that the POWER LED is green. If the POWER LED does not illuminate, disconnect power, and verify polarity.

Push the ejector tab up and closed against the module front panel.

To verify one or both –48 VDC supply voltages, use the SCU terminal and navigate to the following path:

System Status/System Alarms/–48V Bus

COMPLIANCE

This product is NRTL listed to the applicable UL standards. The Total Access 4303 Plus DC Power Supply is intended for installation in a type “B” or “E” enclosure in a Restricted Access Only area. The Total Access 4303 shelf Frame Ground terminal must be connected to an earth ground to ensure that the front panel of the Total Access 4303 Plus DC Power Supply is properly grounded via the backplane connector.

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.