BATTERY
BATTERY BACKUP UNIT | JOBAID | ||
|
| ||
MOUNTING INSTRUCTIONS | BATTERY SPECIFICATIONS |
|
BACKUP
UNIT
P/N: 1175044L2
CLEI: SIMPBBBARA
1 | Unpack the Total Access 750/ 850 Battery Backup Unit and inspect |
for damage. If damage is apparent, refer to your carrier or supplier | |
| for remedy. |
| Note: It is not necessary to remove the batteries during |
| installation process. |
2 | The battery box must be mounted with the following minimum |
clearances: | |
|
|
| Top- 5" (for Total Access 612/616/624) |
| Left |
| Right |
|
|
3 | Using the template provided, mark and drill three pilot holes for #10 |
mounting screws. | |
4 | Insert #10 x 3/ 4" flat- head wood screws (supplied) into the three |
pilot holes, leaving 1/ 16" space between the screw- head and the |
■Batteries: 7 Amp/ hr (4 batteries per pack)
■Case size: 6" W x 3 3/ 4" H x 2 1/ 2" D
■Battery type: Lead acid
■Voltage:
■Backup Time: Up to 8 hours
■Wire Gauge: 18 AWG
■Preferred Temperature: 68º F (20º C)
The device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user's authority to operate this equipment.
1175044L2
BATTERY BACKUP
Note: Battery Backup Unit is designed for use with the Total Access 612, 616, 624,
| backboard. |
| CAUTION: Fully loaded Battery box weighs 30 lbs. |
5 | Mount the battery box on the three support screws on the backboard. |
6 | cover.Remove the two closure screws on the battery box and open the |
7 | Use a long shaft screwdriver to tighten the three support screws. |
Note: The connection for the Total Access 850 will be identical to the Total Access 750.
CAUTION!
During
Total Access 750 wall installation, position the chassis so front panels face up.
Total Access 750
V.35
WARNING: | T1 | Terminal P2 | |
20 Hz FUSE | |||
MUST BE REMOVED |
|
| LX IN |
| access | ||
BEFORE REMOVING COVER. |
| LY IN | |
| cover | ||
| FT1 | EU2 | |
| LX OUT | ||
|
| LY OUT | |
|
|
| EU1 |
|
|
| |
MANAGEMENT |
| ||
| |||
|
|
| MJ |
|
| MJR | |
| DC |
| MJV |
| MJVR | ||
| POWER |
|
|
To Alarms
WARRANTY |
|
|
Warranty for Carrier Network products manufactured by ADTRAN and | ||
supplied under Buyer's order for use in the U. S. is ten (10) years, except | ||
for batteries which carry manufacturer's warranty. For a complete copy of | ||
ADTRAN's U. S. Carrier Network Equipment | ||
Warranty: (877) 457- 5007, Document 414. | ||
TELECOMMUNICATIONS CODES | ||
Code | Input | Output |
IC | — | C |
TC | — | — |
1175044L2
BATTERY BACKUP
AC/DC Power Supply | 120VAC/ | AC ALARM | |
| BATTERY | ||
| 2A 60HZ INPUT OUTPUT |
| |
Battery Charging Unit |
| INPUT | OUTPUT |
|
|
| |
P/N: 1175043Lx | GROUND | + - |
|
AC Power Input | ||
Charging/Discharging Line | ||
|
CAUTION
During wall installation, position the Total Access 612/616/624 as shown in
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
PC | E | — |
MAINTENANCE
9902271 |
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
■Life expectancy: 3- 5 years on standby use
■ Battery performance is adversely affected by extreme emperatures.
■ Old barreries should be recycled. Reference
Total Access 612/616/624
AC Power Input
JOBAid, | Technical Support | Copyright 2002 ADTRAN, All Rights Reserved |