Quick Start Guide
| For more detailed documentation, visit us online at www.adtran.com |
ATLAS 830 | P/N 1200780L1 (AC)/1200781L1 (DC) |
|
|
Reviewing the Rear Panel Design | T1/PRI Monitor Jacks | Network T1/PRI Ports | Optional DC |
Alarm Relay Connection |
| Power Supply | |
|
| P/N 1200229L1 | |
|
|
| |
|
|
| CAUTION: FOR CONTINUED PROTECTION |
|
|
| AGAINST RISK OF FIRE, REPLACE |
|
|
| ONLY WITH SAME TYPE AND RATING |
|
|
| OF FUSE. |
Admin Interface |
|
|
|
ON
OFF
12A/125V
Option Module Slots | Power Supply Slot |
|
- |
+ |
48 VDC, 6A
USE COPPER
CONDUCTORS ONLY
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
Admin Pinout
PIN | NAME | DESCRIPTION |
1 | DCD | Data Carrier Detect (output) |
2 | RD | Receive Data (output) |
3 | TD | Transmit Data (input) |
4 | DTR | Data Terminal Ready (input) |
5 | SG | Signal Ground |
6 | DSR | Data Set Ready (output) |
7 | RTS | Request to Send (input) |
8 | CTS | Clear to Send (output) |
9 | RI | Ring Indicate (output) |
10/100BaseT Ethernet Pinout
PIN | NAME | DESCRIPTION |
1 | TX1 | Transmit Positive |
2 | TX2 | Transmit Negative |
3 | RX1 | Receive Positive |
4,5 | — | Unused |
6 | RX2 | Receive Negative |
7, 8 | — | Unused |
Alarm Relay Connection Pinout
PIN | NAME | DESCRIPTION |
1 | Normaly Closed (NC) | Opens when a selected alarm condition is present. |
2 | Normally Open (NO) | Closes when a selected alarm condition is present. |
3 | Common (COM) | Common connection between external circuitry |
|
| and NC or NO terminal. |
|
|
|
4 | Chassis Ground (GND) |
|
DC Power Supply Connection
(Optional P/N 1200229L1)
PIN | NAME | DESCRIPTION |
1 | + | Ground (GND) |
2 | - |
Quick Start Guide, | Technical Support | Copyright 2002 ADTRAN, All Rights Reserved |