ADTRAN DSU 56 user manual Near END Tests, DTE only Test

Models: DSU 56

1 44
Download 44 pages 49.87 Kb
Page 30
Image 30

Chapter 3. Test Modes

If an EPROM CHECKSUM failure is detected during self test, CS, ALM, PTRN, and ERROR indicators all flash at the end of the self test.

NEAR END TESTS

The local DSU 56/64 can perform the following near end tests:

DTE Only

DTE with Test Pattern

DTE and LOOP (LL)

Loop Only (RT)

DTE ONLY TEST

The DTE ONLY test can test both the DTE interface of the local DSU 56/64 plus its loop transmitter and receiver. For this test, the loop transmit data is connected to the loop receive data at a point close to the physical network interface.

The loopback point and the signal paths for this test are shown in Figure 3-1.

DTE or Test Equipment Interface

TD

RD

 

56/64 DSU

Network

DTE

Loop

Interface

Transmit

Transmit

 

Interface

Interface

 

 

 

Loop TX

 

DTE

 

 

Only

 

 

 

Loop RX

DTE

Loop

 

Receive

Receive

 

Interface

Interface

 

Figure 3-1. DTE Only Test Diagram

3-2

DSU 56/64 User Manual

61200062L1-1

Page 30
Image 30
ADTRAN DSU 56 user manual Near END Tests, DTE only Test