![](/images/new-backgrounds/1203991/20399159x1.webp)
Chapter 3. Test Modes
If an EPROM CHECKSUM failure is detected during self test, CS, ALM, PTRN, and ERROR indicators all flash at the end of the self test.
NEAR END TESTS
The local DSU 56/64 can perform the following near end tests:
•DTE Only
•DTE with Test Pattern
•DTE and LOOP (LL)
•Loop Only (RT)
DTE ONLY TEST
The DTE ONLY test can test both the DTE interface of the local DSU 56/64 plus its loop transmitter and receiver. For this test, the loop transmit data is connected to the loop receive data at a point close to the physical network interface.
The loopback point and the signal paths for this test are shown in Figure
DTE or Test Equipment Interface
TD
RD
| 56/64 DSU | Network |
DTE | Loop | Interface |
Transmit | Transmit |
|
Interface | Interface |
|
|
| Loop TX |
| DTE |
|
| Only |
|
|
| Loop RX |
DTE | Loop |
|
Receive | Receive |
|
Interface | Interface |
|
Figure 3-1. DTE Only Test Diagram
DSU 56/64 User Manual |