Chapter 3. Test Modes
FAR END TESTS
Remote Digital
When the RDL test is initiated at the local DSU 56/64, it commands the remote DSU into loopback with the industry standard V.54 loopback pattern. The loopback point and the signal paths for the remote DSU are the same as the LOOP ONLY test for a local DSU, shown in Figure
To initiate the RDL test, perform the following steps:
1.Press SELECT five times to turn on the RDL test indicator.
2.Press TEST while this test indicator is on.
3.To terminate this test, press TEST.
RDL with Test Pattern (TP)
When the RDL WITH TP test is initiated at the local DSU 56/64, the local DSU commands the remote DSU into loopback with the industry standard V.54 loopback pattern. The loopback point and the signal paths for the remote DSU are the same as the LOOP ONLY test for a local DSU; see Figure
To initiate the RDL WITH TP test, perform the following steps:
1.Press SELECT six times to turn on both the RDL and PTRN test indicators.
2.Press TEST while these test indicators are on.
3.To terminate this test, press the TEST switch.
DSU 56/64 User Manual |