Table F. FNID Unit Specifications

Loop Interface:

 

Modulation Type

2B1Q

Mode

Full Duplex, Echo Cancelling

Number of Pairs

One

Bit Rate

784 kbps

Baud Rate

392K baud

Service Range

Defined by Carrier Service Area Guidelines

Loop Loss

36 dB maximum @ 200 kHz

Bridged Taps

Single Taps < 2 kft, Total Taps < 2.5 kft

Performance

Compliant with Bellcore TA-NWT-001210

Return Loss

20 dB (40 kHz to 200 kHz)

DSL Tx Signal Level

13.5 dBm

Input Impedance

135 Ω

DS1 Channelization

Channels 1-12

Customer Interface:

 

4-wire DS1 (T1.403-compatible)

 

DS1 Signal Output Level

Programmable through FT1 DP at 0, or -15 dB

DS1 Input Signal Level

0, or -15 dB

DS1 Line Coding

AMI, B8ZS

DS1 Framing Format

SF, ESF

Power:

 

Span Power

Selectable: less than -140 VDC (Class A2 with GFI circuit), or less than -190 VDC

 

(Class A2 with GFI circuit)

Locally Powered

-48 V at 75 mA

Clock Sources:

 

Clock Sources

Internal, DSL Loop Derived

Internal Clock Accuracy

±25 ppm, (exceeds Stratum 4). Meets T1.101 timing requirements.

Tests:

 

Diagnostics

Loopback (FNID), initiated with DDS latching loopbacks, initiated with FT1 DP

command. Self-Test.

 

Physical:

 

Dimensions

2.25" High, 8.75" Wide, 10.25" Deep

Weight

4 pounds (standalone)

Environment:

Operating (Standard): -40° to +70°C; Storage: -40° to +85°C

Temperature

Part Numbers:

 

Circuit Pack

1245201L1

 

 

61245201L1-5C

Section 61245201L1-5, Issue 3

13

Page 13
Image 13
ADTRAN T200 FNID specifications Table F. Fnid Unit Specifications