ADTRAN IQ 310 T1 NIM quick start IQ 310 T1 NETWORK INTERFACE MODULE NIM, P/N 1202802L1

Models: IQ 310 T1 NIM

1 2
Download 2 pages 13.32 Kb
Page 1
Image 1
IQ 310 T1 NETWORK INTERFACE MODULE (NIM)

For more detailed documentation, visit us online at www.adtran.com

IQ 310 T1 NETWORK INTERFACE MODULE (NIM)

P/N 1202802L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS (CONTINUED)

 

 

 

 

 

 

 

 

 

 

Environmental

 

 

 

 

 

 

 

 

 

 

 

Operating Temperature:

0 to 50 C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storage Temperature:

-40 to 85 C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relative Humidity:

Up to 95% non-condensing

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

Network Interface

Framing:

SF / ESF with auto detection

Line Coding:

AMI / B8ZS

Input signal:

to -36 dB

Clock Source:

network or internal

Line Build Out:

0, -7.5dB, -15 dB, -22.5dB

Data Rate:

56k or 64k

Connector:

RJ-48

Compliance

FCC Part 15, Class A

FCC Part 68

Industry Canada CS03

UL and CUL

INSTALLATION INSTRUCTIONS

1.Remove the power from the unit.

2.Slide the option module into the option slot until the module is firmly seated against the front of the chassis.

3.Secure the pins at both edges of the module.

4.Connect the cables to the associated device(s).

5.Complete installation of the Base Unit.

6.Restore power to the unit.